Rotation Pulse Meter K3HB-R

:
OMRON

    A digital rotation/pulse meter that features high-speed measurement of 50 kHz.
    [Features]
    · 50 kHz high-speed pulse measurement.
    · Supports high-speed pulse measurement of rotary encoders and various ON/OFF pulse signals up to 50 kHz.
    · Supports rotation measurement of objects rotating at high speeds.
    · Supports 6 types of measurement operations, such as rotation/speed and ratio.
    · This single device supports the 6 measurement operation functions related to rotation/pulse measurement, which are needed to support various pulse measurement applications.
    · Equipped with a position meter.
    · Short body size with a depth (neck-down) of 95 mm.

    Rotation Pulse Meter Specifications

    K3HB-R external appearance

    K3HB-R external appearance

    K3HB-R dimensional outline drawing

    K3HB-R dimensional outline drawing

    Panel machining dimensions

    Panel machining dimensions

    Mounting panel thickness is 1 to 8 mm. Mount horizontally.

    Rating

    Power Supply Voltage100 to 240 V AC, 24 V AC/V DC, DeviceNet Power Supply: 24 V DC
    Allowable Voltage Variation Range85 to 110% of rated power supply voltage, DeviceNet power supply: 11 to 25 V DC
    Power Consumption (At Maximum Load)*1100 to 240 V AC: 18 VA or less, 24 V AC / V DC: 11 VA / 7 W or less
    Current ConsumptionDeviceNet Power Supply: 50 mA Or Less (24 V DC)
    InputNon-voltage contact, voltage pulse, open collector
    External Power Supply12 V DC ±10% 80 mA (type with external power supply only)
    Event Input*2Start-Up Compensation Timer InputNPN open collector or non-voltage contact signal
    Residual voltage at short circuit (residual voltage when ON): 2 V or less
    Current at short circuit (when 0 Ω): 4 mA or less
    Maximum applied voltage: 30 V DC or less
    Leak current (leak current when OFF): 0.1 mA or less
    Hold Input
    Reset Input
    Bank Input
    Output
    (Differs Based On Model)
    Relay Contact Output250 V AC / 30 V DC 5 A (resistive load), mechanical life: 5 million operations, electrical life 100,000 operations
    Transistor OutputMaximum load voltage: 24 V DC, maximum load current: 50 mA, leak voltage: 100 μA or less
    Linear OutputDC 0 to 20 mA / DC 4 to 20 mA: load 500 Ω or less
    Resolution: approx. 10,000, output error: ±0.5% FS
    0 to 5 V DC / 1 to 5 V DC / 0 to 10 V DC: Load: 5 kΩ or more
    Resolution: approx. 10,000, output error: ±0.5% FS
    However, ±0.15 V below 1 V (no output for 0 V or less)
    Display MethodNegative LCD (backlight LED) display
    · 7-segment digital display (character height PV: 14.2 mm [switchable between green and red], SV: 4.9 mm [green])
    Main FunctionsScaling function, measurement operation selection, averaging processing, output hysteresis,
    output OFF delay, output test, teaching, display value selection, display color switching,
    key protect, bank switching, display refresh cycle, MAX/MIN hold, reset
    Operating Temperature RangeWhen In Use-10 to +55°C (No Freezing Or Condensation)
    When Stored-25 to +65°C (No Freezing Or Condensation)
    Operating Humidity RangeWhen Stored25 to 85% RH
    Height2,000 m or less
    AccessoriesIn addition to waterproof packing, fixtures × 2, a terminal cover, a unit sticker, and an instruction manual,
    the DeviceNet type also includes a DeviceNet connector (Hirose Electric: HR31-5.08P-5SC [01]) and a crimp terminal (Hirose Electric: HR31-SC-121). *3

    *1. For DC power supply types, a control power supply capacity of approx. 1 A per unit is required when powering ON. Be especially careful when using multiple units. The S8VS series (OMRON) is recommended for DC power supply.
    *2. A PNP input type is also available.
    *3. For the K3HB series DeviceNet type, it cannot be used with anything other than the included DeviceNet connector. Additionally, the included crimp terminal is for thin cables.

    • *Refer to the catalog for performance tables, output tables, etc.