Power MOS FET Relay G3FM

:
OMRON

    A microload switching SSR with a maximum leakage current of 100 μA. No need for bleeder resistance.
    [Features]
    · Same dimensions as the Model MY (2-pole type).
    · Solid state relay for 1 to 500-mA microload switching.
    · Switches both AC and DC. DC switching has no polarity.
    · Can switch over a wide range of voltages; 19.2 to 264 V AC and 19.2 to 125 V DC.
    · Can switch between AC full-wave rectification and half-wave rectification loads.
    · Directly switches the Model MY (without bleeder resistance.)
    [Applications]
    · Features minimal leakage current—a feature specific to SSRs—and so used when microload switching is necessary.

    Power MOSFET Relay G3FM Specifications

    Power MOSFET Relay G3FM: related images

    Power MOSFET Relay G3FM external appearance

    Power MOSFET Relay G3FM: related images

    G3FM dimensional outline drawing (front view), Units: mm

    Power MOSFET Relay G3FM: related images

    G3FM dimensional outline drawing (side view), Units: mm

    Power MOSFET Relay G3FM: related images

    G3FM terminal layout / internal schematics

    Features

    • Reduces wiring work when combined with the PYF-08-PU Push-In Plus Terminal Block Socket (sold separately)
    • Features a built-in varistor with excellent external surge absorption
    Item
    FormatInputOutput
    Rated VoltageOperating VoltageImpedanceVoltage LevelRated Load VoltageLoad Voltage RangeLoad Current*Inrush
    Current
    Operating VoltageRelease Voltage
    Model G3FM-2R5SLN5 V DC4 to 6 V DC250 Ω ±20%4 V DC max.1 V DC min.24 to 240 V AC
    24 to 110 V DC
    19.2 to 264 V AC
    19.2 to 125 V DC
    1 to 500 mA
    (at 40°C)
    6 A (10 ms)
    12 V DC9.6 to 14.4 V DC600 Ω ±20%9.6 V DC max.
    24 V DC19.2 to 28.8 V DC1.2 kΩ ±20%19.2 V DC max.

    * Differs depending on ambient temperature. For details, see the catalog characteristics data "● Rated Load Current—Ambient Temperature."

    Operating Time5 ms max.
    Release Time10 ms max.
    Output On Voltage Drop3 V (RMS) max.
    Leakage Current0.1 mA max. (at 200 V AC)
    Insulation Resistance100 MΩ min. (with 500 V ohmmeter)
    Dielectric Strength1,500 V AC 50/60 Hz for 1 min 
    Vibration10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
    Shock1,000 m/s2
    Storage Temperature-30 to +100°C (assuming no icing or condensation)
    Ambient Operating Temperature-30 to +80°C (assuming no icing or condensation)
    Ambient Operating Humidity45 to 85% RH
    WeightApprox. 50 g
    • *See the catalog for specifications other than those detailed above.