Digital Daily Time Switch H5F

:
OMRON

    Calendar timer conforming to the CE mark that allows for simple control of the time of day.
    [Features]
    · Days of the week can be selected for operation (however, can set only one pattern of operation days and specified days).
    · Remarkably simple handling of holidays, etc., with the holiday function and easily supports changes to the schedule with semi-automatic operation.
    · Simplified program checks with the test mode function.
    · Product lineup includes embedded and surface mount along with JIS-standardized dimension types.
    [Applications]
    · Optimal when control equipment is required for switching the output signal at the preset time after the start signal is input.
    · Can be used for all kinds of industrial equipment.

    Embedded And Surface Mounted Types Available In Conventional Sizes

    Digital Daily Timer Switch H5F: related image

    24-step ON/OFF time schedule settings

    Digital Daily Timer Switch H5F Outline Drawing And Dimensions

    Digital Daily Timer Switch H5F: related image

    Embedded mounted type (mounting adapter Y92F-30 included)
    Series H5F-A/-B

    Digital Daily Timer Switch H5F: related image

    Surface mounted type
    Series H5F-FA/-FB

    Digital Daily Timer Switch H5F: related image

    Conventional size type
    Series H5F-KA/-KB (vertical direction)
    Series H5F-KAL (horizontal dimension)

    H5F Specifications

    Mounting MethodEmbedded MountingSurface MountingSurface / DIN Rail Mounting (Conventional Type)
    Vertical Direction
    Japanese Specification FormatSeries H5F-ASeries H5F-FASeries H5F-KA
    English Specification FormatSeries H5F-B

    Model Configuration

    Power Supply Voltage100 to 240 V AC, 50/60 Hz (Common)
    Allowable Voltage Range85 to 110% of power supply voltage
    Power ConsumptionApprox. 2.4 VA (At 264 V AC)
    Control OutputContact 1a 250 V AC, 15 A (resistive load)
    24 V DC, 10 A (resistive load)
    Minimum applied load 5 V DC, 100 mA (P level, reference value)
    Operating Temperature Range−10 to +55°C (No Freezing)
    Storage Temperature Range−25 to +65°C (No Freezing)
    Ambient Operating Humidity35 to 85%
    Case ExteriorLight Gray (Munsell 5Y7/1)

    Rating

    Variations In Operating Time(±0.01% ±0.05 s) or less*1
    ±0.01% is the value for the set time interval.
    Set Error
    Voltage Effect
    Temperature Effect
    Electromagnetic Interference (According To EN61326-1)
    Time Accuracy±15 s/month (25°C)
    Compensation Time For Power OutageContinuous 5 years or more (25°C), 10 years or more (25°C, power failure ratio 50% or less)*2
    (With lithium battery)
    Insulation Resistance100 MΩ or more (between conductive part terminal and exposed non-charging metal part, between operation power supply circuit and control output, between discontinuous contacts)
    Withstand Voltage2,000 V AC, 50/60 Hz, 1 min (between conductive part terminal and exposed non-charging metal part, between operation power supply circuit and control output)
    1,000 V AC, 50/60 Hz, 1 min (between discontinuous contacts)
    Noise ResistanceBetween power supply terminals: ±1.5 kV
    Square-wave noise by noise simulator (pulse width 100 ns/1 μs, rise 1 ns)
    VibrationEndurance10 to 55 Hz, half amplitude 0.375 mm, 3 directions, 4 cycles each (8 min/cycle)
    Malfunction10 to 55 Hz, half amplitude 0.25mm, 3 directions, 10 min each
    ShockEndurance300 m/s2, 3 axes each direction, 3 times each
    Malfunction100 m/s2, 3 axes each direction, 3 times each
    LifeMechanical100,000 operations or more (20°C)
    Electrical50,000 operations or more (resistive load, 250 V AC, 15 A)
    50,000 operations or more (motor load, 250 V AC, 1 HP)
    50,000 operations or more (inductive load, 250 V AC, 10 A, cosφ = 0.7)
    50,000 operations or more (lamp load, 100 V AC, 100 W)
    10,000 operations or more (lamp load, 100 V AC, 300 W) (+20°C)
    MassApprox. 115 g (Series H5F-A), Approx. 160 g (Series H5F-KA), Approx. 130 g (Series H5F-FA)

    Performance
    *1. Total error including variations in operating time, set errors, and the effects of voltage and temperature are within (±0.01% ±0.05 s)
    *2. Cumulative time of power failure

    Safety StandardscULus (listing): UL508/CSA C22.2 No. 14
    EN61010-1 (IEC61010-1): Pollution Degree 2 / Overvoltage Category II
    A300 PILOT DUTY
    1/3HP 120 VAC
    VDE0106/part10
    Product Safety of Electrical Appliance and Material
    EMC(EMI) EN61326-1*
    Radiation interference field strength EN55011 Group 1 Class A
    Noise terminal voltage EN55011 Group 1 Class A
    (EMS) EN61326-1*
    Electrostatic discharge immunity EN61000-4-2: 4 kV direct, 8 kV atmospheric
    Field strength immunity EN61000-4-3: 10 V/mAM modulation (80 MHz to 1 GHz, 1.4 to 2 GHz)
    Conductive noise immunity EN61000-4-6: 10 V (0.15 to 80 MHz)
    Burst noise immunity EN61000-4-4: 2 kV power supply line, 1 kV output line
    Surge immunity EN61000-4-5: 1 kV between lines (power supply line, output line), 2 kV between grounds (power supply line, output line)
    Voltage dip / interruption immunity EN61000-4-11: 0.5 cycles, 100% (rated voltage)
    Magnetic field strength immunity EN61000-4-8: 30 A/m

    Applicable standards
    *Industrial electromagnetic environment (EN/IEC61326-1 Table 2)

    Features of this product

    Digital Daily Timer Switch H5F: related image

    Global support
    Conforms to the CE mark, all models conform to finger protection standards, so they can be securely used overseas.

    Digital Daily Timer Switch H5F: related image

    Extensive applications
    Supports 4 different mounting methods and 24-step ON/OFF operation for a variety of applications.

    Digital Daily Timer Switch H5F: related image

    Usage example

    Easily deal with sudden schedule changes using the "holiday function" and "semiautomatic operation."