I/O Relay Terminal G7TC

:
OMRON

    A terminal relay which uses a single cable to connect to all PLC I/O units, helping save on space and helping reduce the amount on panel wiring required.
    [Features]
    · Allows for batch wiring to SYSMAC with a single connector cable, reducing the amount of panel wiring steps and helping save on space.
    · Compact size terminal for both input and output at 182 mm* (W) × 85 mm (D) × 68 (H) mm (*102 mm for 8 point type.)
    · Single-action connection to SBC with a connector. Features a built-in coil surge absorbing element.
    · Features operation indicating LEDs, making it quick and easy to check the ON/OFF status of the I/O signal.
    · Model G3TA I/O solid state relays can also be mounted.
    · Conforms to UL and CSA international standards (except Model G7TC-OC16-1).
    [Applications]
    · Equipment that connects to PLCs, DeviceNet, and CompoNet, helping save on man hours and space.

    Product External Appearance of OMRON Terminal Relays

    G7TC I/O Relay Terminal: related images

    G7TC

    Product Features of Terminal Relays

    G7TC I/O Relay Terminal: related images

    Model G7TC-ID16 / Model G7TC-IA16 external appearance

    G7TC I/O Relay Terminal: related images

    Model G7TC-ID16 / Model G7TC-IA16 dimensional drawing

    G7TC I/O Relay Terminal: related images

    Model G7TC-OC16 / Model G7TC-OC16-1 external appearance

    G7TC I/O Relay Terminal: related images

    Model G7TC-OC16 / Model G7TC-OC16-1 dimensional drawing

    G7TC I/O Relay Terminal: related images

    Model G7TC-OC08 external appearance

    G7TC I/O Relay Terminal: related images

    Model G7TC-OC08 dimensional drawing

    • Terminal Relays, The terminals for input and for output are both compact at 182 (W) (for 8 points:102) × 85 (D) × 68 (H) mm.
    • Use the connector for single-action connection to SBC.
    • Features a built-in coil surge absorber.
    • Immediate recognition of the I/O signal status (ON/OFF) using LED operation indicators.
    • DIN track mounting.
    • Model G3TA I/O solid state relay can also be equipped.
    • UL and CSA international standard certified. (excluding Model G7TC-OC16-1)
    Type of Terminal RelaysModel G7TC-IA16
    For Input, AC Coil
    Model G7TC-ID16
    For Input, DC Coil
    Model G7TC-OC16(-1)
    For Output, DC Coil
    Model G7TC-OC08
    For Output, DC Coil
    Contact Structure1 a × 161 a × 8
    Contact MechanismCrossbar twinSingle
    Contact MaterialAu clad + AgAgInSn
    Contact Resistance *150 mΩ max.
    Operating Time *215 ms max.
    Recovery Time *215 ms max.
    Maximum Switching
    Frequency
    Mechanical18,000 operations/hr
    Rated Load1,800 operations/hr
    Insulation Resistance100 MΩ (500 V ohmmeter)
    Dielectric StrengthBetween Coil and Contacts2,000 V AC 50/60 Hz for 1 min
    Between Contacts of Same Polarity1,000 V AC 50/60 Hz for 1 min
    Between Connectors
    *3
    250 V AC 50/60 Hz for 1 min
    Malfunction Vibration10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude)
    Malfunction Impact200 m/s2
    Noise ResistanceNoise level 1.5 kV, pulse width 100 ns to 1 μs
    Rated Voltage Between Terminal Block + and -Controller (SYSMAC, etc.)
    Input circuit rated voltage
    12 V DC ±5%
    24 V DC ±5%
    Rated Current Between Terminal Block + and -Controller (SYSMAC, etc.)
    Input circuit current × Number of ON points
    12 V DC … 46 mA × Number of ON points
    24 V DC … 25 mA × Number of ON points
    Cable Length
    *4
    Between Controller and
    Main Unit
    Work out based on the cable length guidelines
    Between Main Unit and ExternalReference value: 50 m max.
    (with CVV cable 2 mm2)
    Work out based on load
    Ambient Operating Temperature0 to 55°C (assuming no icing or condensation)
    Ambient Operating Humidity35 to 85% RH
    External Connection Tightening Torque0.78 to 1.18 N·m
    Mounting StrengthNo damage when a tensile force of 49 N is applied for 1 second in each direction. In the direction of the track, the strength is 9.8 N min.
    Terminal StrengthTightening torque: 0.98 N·m, Tensile force: 49 N/1 min
    LED Display ColorRedGreenGreen
    Case ColorTransparent redTransparent greenTransparent
    Coil Surge AbsorberVaristorDiode (1 A, 1,000 V)
    WeightApprox. 640 gApprox. 630 gApprox. 670 gApprox. 350 g

    Note: The above values are initial values of Terminal Relays.
    *1. Measurement condition: 1 A at 5 V DC
    *2. Ambient temperature conditions: 23°C
    *3. Indicates between connector pins 10 and 20, and between 9 and 19.