DC Power Relay (200A Type) G9EC-1

:
OMRON

    A DC power relay capable of interrupting high-voltage, high-DC current loads. A low noise design with a long service life and environmental resistance.
    [Features]
    · The switching section and driving section are gas-injected, hermetically sealed and small, allowing them to interrupt high-capacity loads.
    · Requires no arc space, helping ensure safety and more efficient use of space.
    · The highly reliable contacts are not affected by the ambient atmosphere.
    · Its miniaturization and optimum design ensures no restrictions on the mounting direction.
    · UL/CSA standard UL508 approved.
    [Applications]
    · Can be widely used for FA equipment and non-FA equipment.

    DC Power Relay (200 A Type) G9EC-1 Outline Drawing and Specifications

    Screw terminal type / Model G9EC-1-B outline drawing

    Screw terminal type / Model G9EC-1-B outline drawing

    Dimensional drawing

    Dimensional drawing

    TypeTerminal shapeNumber of Poles
    Contact Configuration
    Coil Rated VoltageFormat
    Coil TerminalContact Terminal
    Switching/current carrying typeScrew terminalScrew terminal1 a24 V DCModel G9EC-1-B
    Rated Voltage (V)Rated Current
    (mA)
    Coil Resistance (Ω)Operating Voltage (V)Release Voltage
    (V)
    Maximum Allowable Voltage
    (V)
    Power Consumption
    (W)
    DC2446951.275% max.
    of rated voltage
    8% min.
    of rated voltage
    110% of rated voltage
    (at 23°C within 10 minutes)
    Approx. 11

    Operating Coil

    • *The figures for the rated current and coil resistance are for a coil temperature of 23°C and have a tolerance of ±10%.
    • The figures for the operating characteristics are for a coil temperature of 23°C.
    • The figure for the maximum allowable voltage is the maximum voltage that can be applied to the relay coil.
    ItemResistive Load
    Model G9EC-1(-B)
    Rated Load400 V DC 200 A
    Rated Carry Current200 A
    Maximum Contact Switching Voltage400 V
    Maximum Contact Switching Current200 A

    Switch

    FormatModel G9EC-1(-B)
    Contact Resistance *130 mΩ max. (Typ. 0.2 mΩ)
    Contact Voltage Drop0.1 V max. (for a carry current of 200 A)
    Operating Time50 ms max.
    Release Time30 ms max.
    Insulation Resistance *2Between Coil And Contact1,000 MΩ min.
    Between Contacts of Same Polarity1,000 MΩ min.
    Dielectric StrengthBetween Coil And Contact2,500 V AC for 1 min
    Between Contacts of Same Polarity2,500 V AC for 1 min
    Impulse Withstand Voltage *34,500 V
    Vibration ResistanceDurability10 to 55 to 10 Hz 0.75-mm single amplitude (Acceleration: 2.94 to 88.9 m/s2)
    Malfunction10 to 55 to 10 Hz 0.75-mm single amplitude (Acceleration: 2.94 to 88.9 m/s2)
    Shock ResistanceDurability490 m/s2
    Malfunction196 m/s2
    Mechanical Durability *4200,000 operations min.
    Electrical Durability (Resistive Load) *5400 V DC 200 A 3,000 operations min.
    Short-Time Carry Current300 A (15 mins.)
    Maximum Interruption Current400 V DC 1,000 A (10 times)
    Overload Interruption400 V DC 700 A (40 times min.)
    Reverse Polarity Interruption200 V DC - 200 A (1,000 times min.)
    Ambient Operating Temperature-40 to +50°C (assuming no icing or condensation)
    Ambient Operating Humidity5 to 85% RH
    Weight (Including Accessories)Approx. 560 g

    Performance
    The above values are initial values at an ambient temperature of 23°C unless otherwise specified.

    *1. Measurement conditions: 5 V DC, 1 A, voltage drop method.
    *2. Measurement conditions: measured with a megohmmeter (500 V DC).
    *3. Measured with a JEC-212 (1981) standard impulse voltage waveform (1.2 × 50 µs).
    *4. Test conditions: switching frequency: 3,600 operations/hr