MELSEC-Q Series Inter-Channel Insulation Pulse Input Unit

:
MITSUBISHI

    - High-speed counter modules, Pulse input module, MELSEC Q series from MITSUBISHI.
    - The Q Series I/O and intelligent function module lineup is extensive and capable of meeting the needs of a wide range of applications.
    - Multi-function counter/timer module (QD65PD2) are Perform extremely accurate position tracking, Multiple functions designed for ease of use and perform sophisticated control using coincidence detection.
    - Channel isolated pulse input module (QD60P8-G) is appropriate for the measurement of input pulse counts (related to speed, revolution, instantaneous flow rate, etc.) and the measurement of quantities (length, cumulative flow, and so forth).

    MELSEC-Q Series Inter-Channel Insulation Pulse Input Unit Specifications

    QD60P8-G

    QD60P8-G image

    QD60P8-G image

    QD60P8-G Performance Specifications

    Number of Channels8 channels
    Computing Speed Switching Settings30 kpps, 10 kpps, 1 kpps, 100 pps, 50 pps, 10 pps, 1 pps, 0.1 pps
    Count Input SignalPhase1-phase input
    Signal Level5 V DC / 12 to 24 V DC
    CounterComputing Speed (Maximum)30 k pulse/s, 10 k pulse/s, 1 k pulse/s, 100 pulse/s, 50 pulse/s, 10 pulse/s, 1 pulse/s, 0.1 pulse/s
    Count RangeNumber of sampling pulses: 16-bit binary (0 to 32,767)
    Integration count values: 32-bit binary (0 to 99,999,999)
    Input pulse values: 32-bit binary (0 to 2,147,483,647)
    ModelLinear counter model, ring counter model
    Minimum Count Pulse Width (Duty Ratio 50%)30 k pulse/s: 33.4μs (ON/OFF 16.7μs each)
    10 k pulse/s: 100μs (ON/OFF 50μs each)
    1 k pulse/s: 1 ms (ON/OFF 0.5 ms each)
    100 pulse/s: 10 ms (ON/OFF 5 ms each)
    50 pulse/s: 20 ms (ON/OFF 10 ms each)
    10 pulse/s: 100 ms (ON/OFF 50 ms each)
    1 pulse/s: 1 s (ON/OFF 0.5 s each)
    0.1 pulse/s: 10 s (ON/OFF 5 s each)
    Dielectric StrengthBetween all AC external terminals as a whole and the earth: 1,500 V AC for 1 minute
    Between a bundle of all DC external terminals and the earth: 500 V AC for 1 minute
    Between channels: 1,780 V AC for one minute
    Insulation ResistanceBetween all AC external terminals as a whole and the earth: 500 V DC, 5 MΩ or more
    External Wiring Connection Method18-point screw terminal block (M3 Screw)
    Number of Occupied Inputs/Outputs32 points (I/O assignment: intelligent 32 points)
    5 V DC Internal Current Consumption0.58 A
    External DimensionsHeight (H)98 mm
    Width (W)27.4 mm
    Depth (D)90 mm
    Weight0.17 kg