Filter Regulator AW20-D to AW60-D, With Backflow Function AW20K-D to AW60K-D

- Please refer to the catalog for details of specifications and materials.
- The product images are representative only. Please refer to the manufacturer's catalog for shape details.
[Features]
・ Improved visibility & environmental resistance
·Ensuring compatibility
·The filter and regulator are integrated to save space and piping
·The backflow function has a built-in mechanism that discharges the air pressure on the outlet side to the inlet side
Dimensional Drawing
Standard (with round pressure gauge)




Plate thickness
AW20-D to AW30-D: MAX. 3.5
AW40-D to AW40-06-D: MAX. 5
| Round Pressure Gauge |
|---|
![]() |
| Compatible Models | Optional Specifications | Semi-Standard | |||||
|---|---|---|---|---|---|---|---|
| With Auto Drain | PC/PA Case | Metal Case | Metal Case with Level Gauge | ||||
| With Drain Cock and Barb Fittings | With Drain Guide | With Drain Cock | With Drain Guide | With Drain Cock | With Drain Guide | ||
| AW20-D | ![]() | ![]() | ![]() | ![]() | |||
| AW30-D to AW60-D | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() |
| Part Number | Standard Specifications | Optional Specifications | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Round Pressure Gauge | Round Pressure Gauge (with color zone) | ||||||||||||||
| P1 | P2 | A | B | CNote: | D | E | F | G | J | K | H | J | H | J | |
| AW20-D | 1/8, 1/4 | 1/8 | 40 | 87.6 | 71.8 | 21 | - | M28 x 1 | 40 | 21 | 5 | ⌀37.5 | 57.5 | ⌀37.5 | 58.5 |
| AW30-D | 1/4, 3/8 | 1/8 | 53 | 115.4 | 86.5 | 26.5 | 30 | M38 × 1.5 | 55 | 26.5 | 3.5 | ⌀37.5 | 63 | ⌀37.5 | 64 |
| AW40-D | 1/4, 3/8, 1/2 | 1/8 | 70 | 147.1 | 91.5 | 35.5 | 38.4 | M42 × 1.5 | 80 | 35.5 | - | ⌀42.5 | 73 | ⌀42.5 | 73 |
| AW40-06-D | 3/4 | 1/8 | 75 | 149.1 | 93 | 35.5 | 38.4 | M42 × 1.5 | 80 | 35.5 | - | ⌀42.5 | 73 | ⌀42.5 | 73 |
| AW60-D | 3/4, 1 | 1/8 | 95 | 234.1 | 155 | 45 | - | - | 30 | 45 | - | ⌀42.5 | 82.5 | ⌀42.5 | 82.5 |
| Part Number | Optional Specifications | Semi-standard Specifications | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Bracket Mounting Dimensions | Panel Mount | With auto condensate drain drain included | PC/PA Case | Metal Case | With level gauge Metal case | |||||||||||||
| With barb fittings | With drain guide | With drain cock | With drain guide | With drain cock | With drain guide | |||||||||||||
| M | N | Q | R | S | T | U | V | W | Y | Z | B | B | B | B | B | B | B | |
| AW20-D | 30 | 34 | 43.9 | 5.4 | 15.4 | 55 | 2.3 | 29.7 | 28.5 | 14 | 6 | 104.9 | - | 91.4 | 87.4 | 93.9 | - | - |
| AW30-D | 41 | 40 | 46 | 6.5 | 8 | 53 | 2.3 | 31.3 | 38.5 | 19 | 7 | 157.1 | 123.9 | 122.2 | 117.8 | 122.3 | 137.8 | 142.3 |
| AW40-D | 50 | 54 | 54 | 8.5 | 10.5 | 70 | 2.3 | 35.5 | 42.5 | 21 | 7 | 186.9 | 155.6 | 153.9 | 149.5 | 154 | 169.5 | 174 |
| AW40-06-D | 50 | 54 | 55.5 | 8.5 | 10.5 | 70 | 2.3 | 37 | 42.5 | 21 | 7 | 188.9 | 157.6 | 155.9 | 151.5 | 156 | 171.5 | 176 |
| AW60-D | 70 | 75 | 66 | 11 | 22 | 113 | 3.2 | - | - | - | - | 273.9 | 242.6 | 240.9 | 236.5 | 241 | 256.5 | 261 |
Note: The C dimension is measured with the handle in the unlocked position.
Product Specifications
Standard Specifications
| Part Number | AW20-D | AW30-D | AW40-D | AW40-06-D | AW60-D | |
|---|---|---|---|---|---|---|
| Pipe Connection Port Diameter | 1/8, 1/4 | 1/4, 3/8 | 1/4, 3/8, 1/2 | 3/4 | 3/4, 1 | |
| Pressure gauge connection port sizeNote 1) | 1/8 | |||||
| Operating fluid | Air | |||||
| Ambient temperature and operating fluid temperatureNote 2) | -5 to 60°C (no freezing) | |||||
| Proof pressure | 1.5 MPa | |||||
| Maximum Operating Pressure | 1.0 MPa | |||||
| Auto Drain Minimum Operating Pressure | N.C. | 0.1 MPa | 0.15 MPa | |||
| N.O. | - | 0.1 MPa | ||||
| Set Pressure Range | 0.05-0.85 MPa | |||||
| Filtration ratingNote 3) | 5 µm | |||||
| Compressed air cleanliness classNote 4) | ISO8573-1:2010 [6:4:4]Note 5) | |||||
| Condensate storage volume | 8 cm3 | 25 cm3 | 45 cm3 | |||
| Case Material | Polycarbonate | |||||
| Case Guard | Semi-standard (Steel Band) | Standard Equipment (Polycarbonate) | ||||
| Structure | Relief Type | |||||
| Mass | 0.18 kg | 0.34 kg | 0.64 kg | 0.69 kg | 1.76 kg | |
Note 1) For models with square built-in pressure gauge or digital pressure switch, there is no pressure gauge connection thread.
Note 2) For models with digital pressure switch, the temperature range is -5 to 50°C.
Note 3) Applies under the following conditions [Test conditions conform to ISO8573-4:2001, test methods conform to ISO12500-3:2009].
Conditions: The element is new, and the processed air flow rate, inlet pressure, and the amount of solid particles on the filter inlet side are stable.
Note 4) The compressed air purity class is indicated based on ISO8573-1:2010 Compressed air - Part 1: Contaminants and purity classes.
For details on this standard, please refer to page 131 of the digital catalog.
Note 5) Indicates the case where the cleanliness class on the inlet side is [7:4:4].