Small Basic Switch [D2MV]

[Features]
· Compact basic switch with high reliability while ultra low load operation.
· Twin cross bar contact with excellent contact reliability.
· High contact power is assured even in ultra low load operation due to the independent internal mechanism.
· Possible to use in applications such as detection of light weight objects.
Dimensional Drawing of OMRON Micro Switches
![Small basic switch [D2MV] Dimensions](http://th.misumi-ec.com/en/linked/vitem/mech/OMR1/221000559071/img/221000559071_001_20230801115854.jpg)
Micro Switches Model D2MV-1-1C□, Model D2MV-01-1C□
![Small basic switch [D2MV] Outline drawing 2](http://th.misumi-ec.com/en/linked/vitem/mech/OMR1/221000559071/img/221000559071_002_20230801115854.jpg)
Micro Switches Model D2MV-01L-1C3
![Small basic switch [D2MV] Outline drawing 2](http://th.misumi-ec.com/en/linked/vitem/mech/OMR1/221000559071/img/221000559071_003_20230801115854.jpg)
Micro Switches Model D2MV-1L111-1C3, Model D2MV-01L111-1C3
![Small basic switch [D2MV] Outline drawing 3](http://th.misumi-ec.com/en/linked/vitem/mech/OMR1/221000559071/img/221000559071_004_20230801115854.jpg)
Micro Switches Model D2MV-1L13-1C3, Model D2MV-01L13-1C3
![Small basic switch [D2MV] Outline drawing 4](http://th.misumi-ec.com/en/linked/vitem/mech/OMR1/221000559071/img/221000559071_005_20230801115854.jpg)
Micro Switches Model D2MV-1L22-1C3, Model D2MV-01L22-1C3
![Small basic switch [D2MV] Outline drawing 5](http://th.misumi-ec.com/en/linked/vitem/mech/OMR1/221000559071/img/221000559071_006_20230801115854.jpg)
Micro Switches Model D2MV-1L2-1C3, Model D2MV-01L2-1C3
Note 1. The dimensional tolerance of Micro Switches all unspecified parts in the above external dimensions is ±0.4 mm.
Note 2. The operating characteristics are for operation in the A direction.
Specification Table of OMRON Micro Switches
■ Micro Switches Performance
| Micro Switchesformat | Micro SwitchesModel D2MV-1 series | Micro Switches Model D2MV-01 series | ||
|---|---|---|---|---|
| Allowable Operating Speed | 1mm to 1m/s (for pin push button type) | |||
| Allowable operating frequency | Mechanical | 300 times/min (for pin push button type) | ||
| Electrical | 60 times/min | |||
| Insulation resistance | 100MΩ or more (DC500V insulation resistance tester) | |||
| Contact resistance (initial value) | 30mΩ or less | 50mΩ or less | ||
| Withstand voltage *1 | Between same-polarity terminals | AC1,000V 50/60Hz 1min | ||
| Between live metal parts and earth | AC1,500V 50/60Hz 1min | |||
| Between each terminal and non-current-carrying metal parts | AC1,500V 50/60Hz 1min | |||
| Vibration *2 | malfunction | Frequency: 10 to 55 Hz, Double amplitude: 1.5 mm | ||
| Impact *2 | Durability | OF0.10N type | Maximum 150m/s2 | |
| OF0.25 to 0.49N type | Up to 400m/s2 | |||
| malfunction | Maximum 100m/s2 | |||
| Durability | Mechanical | Over 10 million times (60 times/min) | ||
| Electrical | Over 500,000 times (30 times/min) | Over 1 million times (30 times/min) | ||
| Protective structure | IEC IP40 | |||
| Operating temperature range | -25 to +80℃ 60% RH or less (but no freezing or condensation) | |||
| Operating humidity range | 85% RH or less (at +5 to +35°C) | |||
| mass | Approx. 6g (pin push button type) | |||
Note: The Micro Switches above are initial values.
- *1. The withstand voltage is the value when a separator is used.
- *2. For pin Micro Switches, the values are for the free position and full travel position, and for lever types, the values are for the full travel position.
The contacts make or break within 1 ms.
■ Contact specifications
| Micro Switches format | Micro Switches Model D2MV-1 series | Micro Switches Model D2MV-01 series | |
|---|---|---|---|
| contact | specification | needle | Twin Crossbar |
| Material | silver | Gold alloy | |
| Interval (standard value) | 0.5mm | ||
| Inrush current | Normally closed | Maximum 1A | Maximum 0.1A |
| Normally open | |||
| Minimum applicable load (reference value) * | DC5V 30mA | DC5V 1mA | |
* For the minimum applicable load, see "Use with Micro Switches" in the Cautions and Prohibitions section.
■ Contact specifications (Micro Switches 1c type [double throw type])
![Small basic switch [D2MV] Product specifications](http://content.misumi-ec.com/image/upload/t_msmwm_wyg/v1/p/jp/product/wysiwyg/221000559071/221000559071_008_20230801115854.gif)
■Micro Switches Type
| Actuator | Operating force (OF) max. | Micro Switches Rating | |
|---|---|---|---|
| 1A | 0.1A | ||
| Micro Switches | 0.10N | Model D2MV-1-1C1 | Model D2MV-01-1C1 |
| 0.25N | - | Model D2MV-01-1C2 | |
| 0.49N | - | Model D2MV-01-1C3 | |
| Hinge/Lever Type | 0.29N | - | Model D2MV-01L-1C3 |
| Hinge/Long Lever Type | 0.15N | Model D2MV-1L111-1C3 | Model D2MV-01L111-1C3 |
| Hinge/R lever type | 0.29N | Model D2MV-1L13-1C3 | Model D2MV-01L13-1C3 |
| Hinge roller short lever type | 0.49N | - | Model D2MV-01L22-1C3 |
| Hinge roller lever type | 0.29N | Model D2MV-1L2-1C3 | Model D2MV-01L2-1C3 |
■ Micro Switches Rating
| Rated voltage | Model D2MV-1 series | Model D2MV-01 series |
|---|---|---|
| Micro Switches Resistive Load | ||
| AC125V | 1A | 0.1A |
| DC30V | 1A | 0.1A |
Note: The above ratings were tested under the following Micro Switches conditions:
(1) Ambient temperature: 20±2°C
(2) Ambient humidity: 65±5% RH
(3) Operation frequency: 30 times/min.
■Safety standard certification rating of Micro Switches
UL (UL1054)/CSA (CSA C22.2 No.55)
| Rated voltage | Micro Switches Model D2MV-1 | Micro Switches Model D2MV-01 |
|---|---|---|
| AC125V | 1A | 0.1A |
| DC30V | 1A | 0.1A |
■ Micro Switches type/shape
![Small basic switch [D2MV] Product specifications 2](http://content.misumi-ec.com/image/upload/t_msmwm_wyg/v1/p/jp/product/wysiwyg/221000559071/221000559071_009_20230801115854.gif)
■ Mounting hole dimensions
![Small basic switch [D2MV] Product specifications 3](http://th.misumi-ec.com/en/linked/vitem/mech/OMR1/221000559071/img/221000559071_010_20230801115854.jpg)
■Operation characteristics
| Micro Switches format | Model D2MV-1-1C1 Model D2MV-01-1C1 | Model D2MV-01-1C2 | Model D2MV-01-1C3 | Model D2MV-01L-1C3 |
|---|---|---|---|---|
| Operating characteristic type | Pin push button type | Hinge/Lever Type | ||
| Operating force OF max. | 0.10N | 0.25N | 0.49N | 0.29N |
| Return force RF min | 0.005N | 0.01N | 0.02N | 0.02N (reference value) |
| Movement PT Max | 1.2mm | 3.3mm | ||
| Movement after action OT min | 1.3mm | 2.1mm | ||
| Differential movement MD Max. | 0.25mm | 0.7mm | ||
| Operating position OP | 14.7±0.4mm | 15.2±1.2mm | ||
| Micro Switches format | Model D2MV-1L111-1C3 Model D2MV-01L111-1C3 | Model D2MV-1L13-1C3 Model D2MV-01L13-1C3 | Model D2MV-01L22-1C3 | Model D2MV-1L2-1C3 Model D2MV-01L2-1C3 |
|---|---|---|---|---|
| Operating characteristic type | Hinge/Long Lever Type | Hinge/R lever type | Hinge roller short lever type | Hinge roller lever type |
| Operating force OF max. | 0.15N | 0.29N | 0.49N | 0.29N |
| Return force RF min | 0.01N (reference value) | 0.02N (reference value) | 0.04N (reference value) | 0.02N (reference value) |
| Movement PT Max | 6.0mm | 3.3mm | 1.7mm | 3.3mm |
| Movement after action OT min | 4.0mm | 1.9mm | 1.0mm | 2.1mm |
| Differential movement MD Max. | 1.4mm | 0.7mm | 0.4mm | 0.7mm |
| Operating position OP | 15.2±2.6mm | 18.7±1.2mm | 20.7±0.6mm | 20.7±1.2mm |
Note: The RF reference value is the value when the lever is mounted in a direction that does not apply weight to the push button.
Selection Support Information of OMRON Micro Switches
![Small basic switch [D2MV] Selection support](http://th.misumi-ec.com/en/linked/vitem/mech/OMR1/221000559071/img/221000559071_007_20230801115854.jpg)
Cautions and Prohibitions of OMRON Micro Switches
OMRON Micro Switches Safety Precautions
Do not subject the Micro Switches
to strong shocks as this is a low load switch and may cause damage to the internal mechanism.
●About soldering
- As a guideline, the soldering time for connecting to the soldering terminals should be less than 5 seconds with a 60W soldering iron (tip temperature +250 to +350°C), and no external force should be applied for 1 minute after soldering
. Use the minimum amount of flux possible. If flux gets inside the switch, it may cause contact failure.
OMRON Micro Switches Usage Notes
● Regarding mounting
, use M3 screws and securely attach using flat washers, spring washers, etc. The tightening torque should be 0.39 to 0.59 N·m.
Regarding the mounting direction
, for Micro Switches models with an actuator, install the switch in a direction that does not apply the actuator's own weight to the switch. This is a low load switch and has a small return force, which may cause the switch to not return properly.
If a switch for general load is used when opening and closing a microload circuit, it may cause poor contact. We recommend that you use the switch within the range of use, referring to the diagram on the right. Even if a Micro Switchestype is used within the area shown in the diagram on the right, if the load generates an inrush current when opening and closing, the contacts will wear out rapidly and durability will decrease, so insert a contact protection circuitas necessary. The minimum applicable load is the N-level reference value. This represents thefailure level at a confidence level of 60% (λ60
). (JIS C5003)
λ60=0.5×10-6/times indicates that the failure rate is estimated to be 1/2,000,000 times or less at a confidence level of 60%.
![Small basic switch [D2MV] Precautions](http://th.misumi-ec.com/en/linked/vitem/mech/OMR1/221000559071/img/221000559071_011_20230801115854.jpg)