TRVVPS Shielded Robot Cables 300V, Twisted, High Flexibility

:
MISUMI
- **RoHS Compliant is available for some part numbers.
Please contact with MISUMI for detail effective date.
RoHS Compliant Product
Product Features of Machinery Robot Cables
.jpg)
Product Overview of Machinery Robot Cables
High-Speed 10 Million Times Twisted Pair Shielded TRVV Machinery Machinery Robot Cables 300V
● Motion Class: Equivalent to MISUMI CLASS B 10 Million Times Machinery Robot Cables
● Machinery Robot Cables Sheath : Black, PVC Conductor: Pure Copper
● Machinery Robot Cables suitable for flexible applications, recommended for combination with drag chains (cannot be used for robot multi-axis motion) Recommended drag chains for combination:
● 100m of Machinery Robot Cables whole roll orders, CE certified
● Motion Class: Equivalent to MISUMI CLASS B 10 Million Times Machinery Robot Cables
● Machinery Robot Cables Sheath : Black, PVC Conductor: Pure Copper
● Machinery Robot Cables suitable for flexible applications, recommended for combination with drag chains (cannot be used for robot multi-axis motion) Recommended drag chains for combination:

● 100m of Machinery Robot Cables whole roll orders, CE certified
| Type | Section Area (mm²) | AWG | Core Number Range |
| CLASS-B E-GR1000-TRVV Non-Shielded | 0.2 | 24 | 2-20 |
| 0.3 | 23 | ||
| 0.5 | 20 | ||
| 0.75 | 18 | 2-12 | |
| CLASS-B E-GR1000-TRVVPS Twisted Pair Shielded | 0.12 | 26 | 2P-5P |
| 0.2 | 24 | 1P-20P | |
| 0.3 | 23 | ||
| 0.5 | 20 | 1P-6P |
Specifications Overview of Machinery Robot Cables
● Cross-sectional Structure

● Core Wire Identification
* The description of insulation color is the reference value and may differ from those of the material objects
Blue (Red 1): refers to the marking of 1 red dot on blue insulation, Orange (White 2): refers to the marking of 2 white dots on orange insulation, and so on

● Core Wire Identification
| Core Wire | 1P | 2P | 3P | 4P | 5P | 6P | 7P |
| Insulation Color | Blue * Orange | Green * Brown | Red * Gray | Yellow * Black | Pink * Purple | Green (Red 1) * White | Orange (White 1) * Green (White 1) |
| Core Wire | 8P | 9P | 10P | 11P | 12P | 13P | 14P |
| Insulation Color | Brown (White 1) * Gray (White 1) | Red (White 1) * Black (White 1) | Yellow (Black 1) * Pink (Black 1) | Blue (Black 1) * Orange (Black 1) | Brown (Black 1) * Green (Black 1) | Red (Black 1) * Gray (Black 1) | Orange (White 2) * Green (White 2) |
| Core Wire | 15P | 16P | 17P | 18P | 19P | 20P | |
| Insulation Color | Brown (White 2) * Gray (White 2) | Red (White 2) * Black (White 2) | Yellow (Black 2) * Pink (Black 2) | Blue (Black 2) * Orange (Black 2) | Brown (Black 2) * Green (Black 2) | Red (Black 2) * Gray (Black 2) |
Blue (Red 1): refers to the marking of 1 red dot on blue insulation, Orange (White 2): refers to the marking of 2 white dots on orange insulation, and so on
●Drag chain test standard


●Printing reference

* All printed characters on the cable appear in a single row
* The above print characters serve as an example of usage, and the actual print characters may vary with specification (numbre of wire cores/cross section)

* All printed characters on the cable appear in a single row
* The above print characters serve as an example of usage, and the actual print characters may vary with specification (numbre of wire cores/cross section)
Specification Table of Machinery Robot Cables
| Type | Cross Section (mm²) | Number of Pairs (Twisted Pair Structure) 1P=2 Cores | AWG | Number of Wire Cores | Cable O.D. (mm) | Reference Mass (kg/km) | Electrical Properties | Conductor (Non-Electroplating) | Insulation (PVC) | Wire Core O.D. approx. (mm) | Sheath (PVC) | ||||
Allowable Current MAX A (30℃) | Conductor Resistance Ω/km (20℃) | Insulation Properties MΩ/km (20℃) | Max Voltage V/minute | Core Wire Structure pcs/mm | O.D. approx. (mm) | Thickness (mm) | Thickness (mm) | ||||||||
| 10 Million Times Machinery Robot Signal Cables E-GR1000-TRVVPS | 0.12 | 2P | 26 | 4 | 5.6 | 50 | 3.3 | 124 or Less | 10 or More | 2000 | 30/0.08 | 0.51 | 0.3 | 1.11 | 0.9 |
| 3P | 6 | 6.3 | 62 | 2.9 | 0.9 | ||||||||||
| 4P | 8 | 6.7 | 72 | 2.6 | 0.9 | ||||||||||
| 5P | 10 | 7.3 | 84 | 2.4 | 0.9 | ||||||||||
| 0.2 | 1P | 24 | 2 | 4.7 | 37 | 6.0 | 87.6 or Less | 10 or More | 2000 | 41/0.08 | 0.59 | 0.3 | 1.19 | 0.9 | |
| 2P | 4 | 5.8 | 55 | 4.7 | 0.9 | ||||||||||
| 3P | 6 | 6.5 | 66 | 4.0 | 0.9 | ||||||||||
| 4P | 8 | 7.0 | 78 | 3.6 | 0.9 | ||||||||||
| 5P | 10 | 7.8 | 93 | 3.4 | 1 | ||||||||||
| 6P | 12 | 8.4 | 106 | 3.2 | 1 | ||||||||||
| 20P | 40 | 13.1 | 269 | 2.2 | 1.1 | ||||||||||
| 0.3 | 1P | 23 | 2 | 4.9 | 44 | 7.4 | 63.2 or Less | 10 or More | 2000 | 60/0.08 | 0.72 | 0.3 | 1.32 | 0.9 | |
| 2P | 4 | 6.2 | 66 | 5.9 | 0.9 | ||||||||||
| 3P | 6 | 7.0 | 82 | 5.1 | 0.9 | ||||||||||
| 4P | 8 | 7.6 | 97 | 4.6 | 0.9 | ||||||||||
| 5P | 10 | 8.2 | 116 | 4.3 | 0.9 | ||||||||||
| 6P | 12 | 9.0 | 134 | 4.0 | 1 | ||||||||||
| 8P | 16 | 10.4 | 177 | 3.8 | 1 | ||||||||||
| 10P | 20 | 10.7 | 189 | 3.7 | 1.1 | ||||||||||
| 20P | 40 | 14.5 | 337 | 2.7 | 1.2 | ||||||||||
| 0.5 | 1P | 20 | 2 | 5.4 | 50 | 10.5 | 34.4 or Less | 10 or More | 2000 | 108/0.08 | 0.96 | 0.3 | 1.56 | 0.9 | |
| 2P | 4 | 6.9 | 83 | 8.3 | 0.9 | ||||||||||
| 3P | 6 | 7.9 | 108 | 7.3 | 0.9 | ||||||||||
| 4P | 8 | 8.7 | 134 | 6.5 | 1 | ||||||||||
| 5P | 10 | 9.5 | 156 | 6.1 | 1 | ||||||||||
| 6P | 12 | 10.4 | 186 | 5.7 | 1.1 | ||||||||||
Product Feature of Machinery Robot Cables
| Item | Specifications | Conditions | Note | ||
Insulation Properties | Tensile Strength | (Lbf/in2) | ![]() | - | ![]() |
| (Mpa) | |||||
| Elongation | (%) | ||||
| Tensile Strength after Aging | (%) | ||||
| Elongation after Aging | (%) | ||||
| Aging Conditions | 168 Hours at 80℃ | ||||
| Tensile Strength | (Lbf/in2) | 1500 or More | - | Test method: ·Refer to UL758 | |
| (Mpa) | 10.3 or More | - | |||
| Elongation | (%) | 100 or More | - | ||
| Tensile Strength after Aging | (%) | 70 or More | - | ||
| Elongation after Aging | (%) | 65 or More | - | ||
| Aging Conditions | 168 Hours at 113℃ | ||||
Coating Properties | Tensile Strength | (Lbf/in2) | ![]() | - | ![]() |
| (Mpa) | |||||
| Elongation | (%) | ||||
| Tensile Strength after Aging | (%) | ||||
| Elongation after Aging | (%) | ||||
| Aging Conditions | 168 Hours at 80℃ | ||||
| Tensile Strength | (Lbf/in2) | 1500 or More | - | Test method: ·Refer to UL758 ·Flame Retardance Test VW-1 | |
| (Mpa) | 10.3 or More | - | |||
| Elongation | (%) | 100 or More | - | ||
| Tensile Strength after Aging | (%) | 70 or More | - | ||
| Elongation after Aging | (%) | 65 or More | - | ||
| Aging Conditions | 168 Hours at 113℃ | ||||
Example Use of Machinery Robot Cables

* Machinery Robot Cables for wiring in the moving part of the machine, the appropriate cable must be selected.
Otherwise, the cable will be entangled with the movement of the machine, damaging the cable and stopping the machine.
Related Products of Machinery Robot Cables
Specification Table

| Type | Cross Section (mm²) | Number of Pairs (Twisted Pair Structure) 1P=2 Cores | AWG | Number of Wire Cores | Cable O.D. (mm) | Reference Mass (kg/km) | Electrical Properties | Conductor (Non-Electroplating) | Insulation (PVC) | Wire Core O.D. approx. (mm) | Sheath (PVC) | ||||
| Allowable Current MAX A(30℃) | Conductor Resistance Ω/km (20℃) | Insulation Properties MΩ/km (20℃) | Max Voltage V/minute | Core Wire Structure pcs/mm | O.D. approx. (mm) | Thickness (mm) | Thickness (mm) | ||||||||
| 10 Million Times Machinery Robot Signal Cables E-GR1000-TRVVPS | 0.12 | 2P | 26 | 4 | 5.6 | 50 | 3.3 | 124 or Less | 10 or More | 2000 | 30/0.08 | 0.51 | 0.3 | 1.11 | 0.9 |
| 3P | 6 | 6.3 | 62 | 2.9 | 0.9 | ||||||||||
| 4P | 8 | 6.7 | 72 | 2.6 | 0.9 | ||||||||||
| 5P | 10 | 7.3 | 84 | 2.4 | 0.9 | ||||||||||
| 0.2 | 1P | 24 | 2 | 4.7 | 37 | 6.0 | 87.6 or Less | 10 or More | 2000 | 41/0.08 | 0.59 | 0.3 | 1.19 | 0.9 | |
| 2P | 4 | 5.8 | 55 | 4.7 | 0.9 | ||||||||||
| 3P | 6 | 6.5 | 66 | 4.0 | 0.9 | ||||||||||
| 4P | 8 | 7.0 | 78 | 3.6 | 0.9 | ||||||||||
| 5P | 10 | 7.8 | 93 | 3.4 | 1 | ||||||||||
| 6P | 12 | 8.4 | 106 | 3.2 | 1 | ||||||||||
| 20P | 40 | 13.1 | 269 | 2.2 | 1.1 | ||||||||||
| 0.3 | 1P | 23 | 2 | 4.9 | 44 | 7.4 | 63.2 or Less | 10 or More | 2000 | 60/0.08 | 0.72 | 0.3 | 1.32 | 0.9 | |
| 2P | 4 | 6.2 | 66 | 5.9 | 0.9 | ||||||||||
| 3P | 6 | 7.0 | 82 | 5.1 | 0.9 | ||||||||||
| 4P | 8 | 7.6 | 97 | 4.6 | 0.9 | ||||||||||
| 5P | 10 | 8.2 | 116 | 4.3 | 0.9 | ||||||||||
| 6P | 12 | 9.0 | 134 | 4.0 | 1 | ||||||||||
| 8P | 16 | 10.4 | 177 | 3.8 | 1 | ||||||||||
| 10P | 20 | 10.7 | 189 | 3.7 | 1.1 | ||||||||||
| 20P | 40 | 14.5 | 337 | 2.7 | 1.2 | ||||||||||
| 0.5 | 1P | 20 | 2 | 5.4 | 50 | 10.5 | 34.4 or Less | 10 or More | 2000 | 108/0.08 | 0.96 | 0.3 | 1.56 | 0.9 | |
| 2P | 4 | 6.9 | 83 | 8.3 | 0.9 | ||||||||||
| 3P | 6 | 7.9 | 108 | 7.3 | 0.9 | ||||||||||
| 4P | 8 | 8.7 | 134 | 6.5 | 1 | ||||||||||
| 5P | 10 | 9.5 | 156 | 6.1 | 1 | ||||||||||
| 6P | 12 | 10.4 | 186 | 5.7 | 1.1 | ||||||||||