Bushings for Locating Pins Shouldered, Configurable, Thin Wall

:
MISUMI
Product Overview
The fixture bushing is a mechanical positioning part that is used in conjunction with a positioning pin to achieve a guiding effect, in which the shouldered, custom dimension, thin wall type offers a wide range of dimensions and specifications, easy to install, suitable for bushings with compact spacing, and can effectively prevent the rapid wear of the workpiece.
Dimensional Drawing

The p7 type has a larger inner diameter shrinkage rate compared to the m7 type, so be careful when machining holes. (See Precautions for the inner diameter change after press-fit)
The I.D. tolerance of bushing is high. If a vernier caliper is used for detection, the measurement result will be too small. It is recommended to use a high-precision measuring tool (internal micrometer or plug gauge, etc.) for detection.Specifications Overview
■Material Specification Table
If there are requirements for rust prevention, give priority to products with surface treatment of electroless nickel plating.
| Type | Material | Surface Treatment | Hardness | |
| p7 | m7 | |||
| E-JBHUFP | E-JBHUF | Equivalent to 9CrWMn (Alloy Tool Steel or Bearing Steel) | - | 55HRC~ |
| E-JBHUFBP | E-JBHUFB | Equivalent to 9CrWMn (Alloy Tool Steel or Bearing Steel) | Ferroferric Oxide Protective Film | 55HRC~ |
| E-JBHUFMP | E-JBHUFM | Equivalent to 9CrWMn (Alloy Tool Steel or Bearing Steel) | Electroless Nickel Plating | 55HRC~ |
| E-JBHUFCP | E-JBHUFC | Martensitic stainless steel | - | 45HRC~ |
If there are requirements for rust prevention, give priority to products with surface treatment of electroless nickel plating.Specification Table
| Part Number | P0.01mm increments | L0.1mm increments | Wall Thickness(N) | H | T | |||
Type | D | D Tolerance | ||||||
| p7 | m7 | |||||||
| (p7) E-JBHUFP E-JBHUFBP E-JBHUFMP E-JBHUFCP (m7) E-JBHUF E-JBHUFB E-JBHUFM E-JBHUFC | 5 | +0.024 +0.012 | +0.016 +0.004 | 2.20~ 3.00 | 3.00~5.00 | 1.00~1.40 | 9 | 2.5 |
| 6 | +0.030 +0.015 | +0.021 +0.006 | 3.00~4.00 | 3.00~5.50 | 1.00~1.50 | |||
| 7 | 3.51~ 5.00 | 3.0~ 6.0 | 1.00~1.74 | 11 | ||||
| 8 | 4.51~ 6.00 | 3.0~10.0 | 12 | 3 | ||||
| 9 | 4.51~ 6.50 | 1.25~2.24 | 13.5 | |||||
| 10 | 6.51~ 8.00 | 3.0~15.0 | 1.00~1.74 | 14 | ||||
| 11 | +0.036 +0.018 | +0.025 +0.007 | 8.00~ 9.00 | 1.00~1.50 | 15 | |||
| 12 | 8.51~ 9.00 | 1.50~1.74 | 16 | 4 | ||||
| 13 | 8.51~10.00 | 10.0~35.0 | 1.50~2.24 | 17 | ||||
| 14 | 9.00~11.00 | 1.50~2.50 | 18 | |||||
| 15 | 10.51~12.00 | 1.50~2.24 | 19 | |||||
| 17 | 10.51~13.00 | 2.00~3.24 | 21 | 5 | ||||
| 18 | 12.51~14.00 | 2.00~2.74 | 22 | |||||
| 19 | +0.043 +0.022 | +0.029 +0.008 | 5.0~35.0 | 2.50~3.25 | 24 | |||
| 20 | 13.51~15.00 | 10.0~35.0 | 2.50~3.24 | 26 | ||||
| 21 | 13.51~15.00 | 5.0~35.0 | 2.50~3.75 | |||||
| 22 | 13.51~17.00 | 10.0~35.0 | 2.50~4.24 | |||||
| 25 | 15.51~19.00 | 3.00~4.74 | 30 | |||||
| 26 | 16.51~20.00 | 3.00~4.74 | ||||||
| 30 | 20.51~24.00 | 3.00~4.74 | 35 | 6 | ||||
| 31 | +0.051 +0.026 | +0.034 +0.009 | 20.51~24.00 | 5.0~35.0 | 3.50~5.24 | 36 | ||
| 35 | 25.01~29.00 | 12.0~50.0 | 3.00~4.99 | 40 | ||||
When P≤3.59, L+T≤P×2.5 When P≥3.60,L+T≤P×3.0Product Features
Precautions
①Dimensional tolerance and fit parameter table For details, click
Dimensional Tolerance Fit Table
②Change in inner diameter of the fixture bushing during press-fit
■Change in inner diameter of the fixture bushing during press-fit
The fixture bushing shrinks when press-fitted.
The shrinkage rate varies depending on material of mounting part and D dimension tolerance of bushing. ③Reference table for common dimensions without indicated tolerance (medium accuracy m) For details, click
Table of Dimensions Without Indicated Tolerance
Dimensional Tolerance Fit Table②Change in inner diameter of the fixture bushing during press-fit
■Change in inner diameter of the fixture bushing during press-fit
The fixture bushing shrinks when press-fitted.
The shrinkage rate varies depending on material of mounting part and D dimension tolerance of bushing.
【Example of Shrinkage during Press-Fit】
βDimension (when mounting hole is H7)
| D Dimension Tolerance | ||
| Mounting Material | m7 | p7 |
| Steel | αX99.93% | αX99.90% |
| Aluminum Alloy | αX99.96% | αX99.93% |
Table of Dimensions Without Indicated ToleranceExample of Use
Application Industries
| Lithium battery | Smart Phones | Electronic & Electrical | ||
![]() | ![]() | ![]() | ||
| Semiconductor | Medical | Food | ||
![]() | ![]() | ![]() |
Related Products
| Locating Pins Large Head, Tapered | Bushings for Fixtures Configurable, Straight, Thin Wall | Small Diameter Locating Pins Straight | ||
![]() | ![]() | ![]() | ||
| Recommended model: KFAMS6-P10-L6-B3-E5-A30 | Recommended model: JBAF10-P4-L8.5 | Recommended model: SPKS-D1-L5 | ||
| Advantages: suitable for various working conditions, widely used | Advantages: easy to install, rich in specifications | Advantages: suitable for use in confined space |
Related Documents
①Positioning technology reference information Click
Positioning Technology
②Surface treatment related anti-rust ability salt spray test reference Click
Anti-rust Reference for Metal
Positioning Technology②Surface treatment related anti-rust ability salt spray test reference Click
Anti-rust Reference for Metal
Material
Surface Treatment
Hardness
P
L
Type
D