(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Brand |
|
---|---|
CAD |
|
Days to Ship |
|
6 itemsMặt hàng
You can add up to 6 items per a category to the compare list.
FMR Combination (Modular Type Standard) C*030/C2530 Series
CKD
Note: CAD data of this series is being revised. Please wait till the corrections are done.[Features]· Boost your system with modularization.· Dual element construction provides long life.
Regulator Unit Combination | Connection Dia. | Filter, Filtration Level | Compressed Air Quality | Max. Operating Pressure(MPa) | Relief Mechanism | Flow Direction | Drain Cock | Pressure Gauge |
---|---|---|---|---|---|---|---|---|
Filter + Micro Mist Filter + Regulator | G1/2 | 0.3µm / 5µm | General Quality Dry Air | 1 | Non-Relief / Relief | Standard Flow (Left to Right) / Reverse Flow (Right to Left) | Manual / Automatic | None (Pressure Port Plug available) / None (Pressure Port Plug not available) / With Standard Pressure Gauge / With Pressure Switch / With Pressure Sensor |
Days to Ship: Số ngày giao hàng: 15 Day(s) or more |
You can add up to 6 items per a category to the compare list.
Modular type filter and regulator standard white series
CKD
Boost your system with modularization. Dual element construction provides long life. Note: CAD data of this series is being revised. Please wait till the corrections are done.
Regulator Unit Combination | Connection Dia. | Filter, Filtration Level | Compressed Air Quality | Max. Operating Pressure(MPa) | Relief Mechanism | Flow Direction | Drain Cock | Pressure Gauge |
---|---|---|---|---|---|---|---|---|
Filter Regulator | G1/2 | 0.3µm / 5µm | General Quality Dry Air | 1 | Non-Relief / Relief | Standard Flow (Left to Right) / Reverse Flow (Right to Left) | Manual / Automatic / Auto/Manual | None (Pressure Port Plug available) / None (Pressure Port Plug not available) / With Standard Pressure Gauge / With Pressure Switch / With Pressure Sensor |
Days to Ship: Số ngày giao hàng: 14 Day(s) or more |
You can add up to 6 items per a category to the compare list.
Modular type reverse filter and regulator standard white series
CKD
Boost your system with modularization. Dual element construction provides long life. Note: CAD data of this series is being revised. Please wait till the corrections are done.[Features]· Series featuring built in reverse flow feature, 5μm dust removal, and 0.3μm tar removal
Regulator Unit Combination | Connection Dia. | Filter, Filtration Level | Compressed Air Quality | Max. Operating Pressure(MPa) | Relief Mechanism | Flow Direction | Drain Cock | Pressure Gauge |
---|---|---|---|---|---|---|---|---|
Filter Regulator | G1/2 | 0.3µm / 5µm | General Quality Dry Air | 1 | Non-Relief / Relief | Standard Flow (Left to Right) / Reverse Flow (Right to Left) | Manual / Automatic / Auto/Manual | None (Pressure Port Plug available) / None (Pressure Port Plug not available) / With Standard Pressure Gauge / With Pressure Switch / With Pressure Sensor |
Days to Ship: Số ngày giao hàng: 14 Day(s) or more |
You can add up to 6 items per a category to the compare list.
FRL Combination (Modular Type Standard) C*000/C*500 Series
CKD
Boost your system with modularization. Dual element construction provides long life. Note: CAD data of this series is being revised. Please wait till the corrections are done.[Features]· Compact modularization: Design for each F.R.L device focused on making it more compact. Assembled dimensions are accurately calculated with a simple calculation.· Lightweight: The material combination allows for both strength and low weight.· Long life element: The elements are constructed from a unique fiber structure that is rough on the surface and becomes finer the further inward it goes (PAT.PEND). Almost no clogs. No rust concerns.· Space-saving embedded pressure meter: Past models had a pressure meter that stuck out of the front surface, wasting space or being at risk of striking the employees. This embedded design is both clean and an improvement to safety.· Prevents oil drips when reverse pressure is applied such as when residual exhaust valves release pressure.· Taking safety into further consideration, this device is equipped with a corrosive resistant plastic bowl.· Gauge plug is sealed even here a pipe plug is not installed.
Regulator Unit Combination | Connection Dia. | Filter, Filtration Level | Compressed Air Quality | Max. Operating Pressure(MPa) | Relief Mechanism | Flow Direction | Drain Cock | Pressure Gauge |
---|---|---|---|---|---|---|---|---|
Filter + Regulator + Lubricator | G1/2 | 0.3µm / 5µm | General Quality Dry Air | 1 | Non-Relief / Relief | Standard Flow (Left to Right) / Reverse Flow (Right to Left) | Manual / Automatic | None (Pressure Port Plug available) / None (Pressure Port Plug not available) / With Standard Pressure Gauge |
Days to Ship: Số ngày giao hàng: 29 Day(s) or more |
You can add up to 6 items per a category to the compare list.
FM Combination (Modular Type Standard) C*060 Series
CKD
Boost your system with modularization. Dual element construction provides long life. Note: CAD data of this series is being revised. Please wait till the corrections are done.
Regulator Unit Combination | Connection Dia. | Filter, Filtration Level | Compressed Air Quality | Max. Operating Pressure(MPa) | Relief Mechanism | Flow Direction | Drain Cock | Pressure Gauge |
---|---|---|---|---|---|---|---|---|
Filter + Mist Filter | G1/2 | 0.3µm / 5µm | General Quality Dry Air | 1 | - | Standard Flow (Left to Right) / Reverse Flow (Right to Left) | Manual / Automatic | - |
Days to Ship: Số ngày giao hàng: 15 Day(s) or more |
You can add up to 6 items per a category to the compare list.
Modular type WL combination standard white series
CKD
Boost your system with modularization. Dual element construction provides long life. Note: CAD data of this series is being revised. Please wait till the corrections are done.[Features]· Its elasticity and flexibility allows it to be used for piping in even tight spaces.· TAC duct aluminum can shrink to 1/5 of its length, and TAC duct aluminum 2 can shrink to 1/10 of its length. This allows it to be stored compactly so it does not take up much storage space.· Can withstand bending multiple times and is resistant to heat (up to 80°C)
Regulator Unit Combination | Connection Dia. | Filter, Filtration Level | Compressed Air Quality | Max. Operating Pressure(MPa) | Relief Mechanism | Flow Direction | Drain Cock | Pressure Gauge |
---|---|---|---|---|---|---|---|---|
Filter Regulator + Lubricator | G1/2 | 0.3µm / 5µm | General Quality Dry Air | 1 | Non-Relief / Relief | Standard Flow (Left to Right) / Reverse Flow (Right to Left) | Manual / Automatic | None (Pressure Port Plug available) / None (Pressure Port Plug not available) / With Standard Pressure Gauge |
Days to Ship: Số ngày giao hàng: 29 Day(s) or more |
BrandNhãn hiệu |
---|
Product SeriesDòng sản phẩm |
CADCAD |
From |
Days to ShipSố ngày giao hàng |
Regulator Unit Combination |
Connection Dia. |
Filter, Filtration Level |
Compressed Air Quality |
Max. Operating Pressure(MPa) |
Relief Mechanism |
Flow Direction |
Drain Cock |
Pressure Gauge |
You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | |
BrandNhãn hiệu | CKD | CKD | CKD | CKD | CKD | CKD |
Product SeriesDòng sản phẩm | Modular type reverse filter and regulator standard white series | |||||
CADCAD |
|
|
|
|
|
|
From | - | - | - | - | - | - |
Days to ShipSố ngày giao hàng | 15 Day(s) or more | 14 Day(s) or more | 14 Day(s) or more | 29 Day(s) or more | 15 Day(s) or more | 29 Day(s) or more |
Regulator Unit Combination | Filter + Micro Mist Filter + Regulator | Filter Regulator | Filter Regulator | Filter + Regulator + Lubricator | Filter + Mist Filter | Filter Regulator + Lubricator |
Connection Dia. | G1/2 | G1/2 | G1/2 | G1/2 | G1/2 | G1/2 |
Filter, Filtration Level | 0.3µm / 5µm | 0.3µm / 5µm | 0.3µm / 5µm | 0.3µm / 5µm | 0.3µm / 5µm | 0.3µm / 5µm |
Compressed Air Quality | General Quality Dry Air | General Quality Dry Air | General Quality Dry Air | General Quality Dry Air | General Quality Dry Air | General Quality Dry Air |
Max. Operating Pressure(MPa) | 1 | 1 | 1 | 1 | 1 | 1 |
Relief Mechanism | Non-Relief / Relief | Non-Relief / Relief | Non-Relief / Relief | Non-Relief / Relief | - | Non-Relief / Relief |
Flow Direction | Standard Flow (Left to Right) / Reverse Flow (Right to Left) | Standard Flow (Left to Right) / Reverse Flow (Right to Left) | Standard Flow (Left to Right) / Reverse Flow (Right to Left) | Standard Flow (Left to Right) / Reverse Flow (Right to Left) | Standard Flow (Left to Right) / Reverse Flow (Right to Left) | Standard Flow (Left to Right) / Reverse Flow (Right to Left) |
Drain Cock | Manual / Automatic | Manual / Automatic / Auto/Manual | Manual / Automatic / Auto/Manual | Manual / Automatic | Manual / Automatic | Manual / Automatic |
Pressure Gauge | None (Pressure Port Plug available) / None (Pressure Port Plug not available) / With Standard Pressure Gauge / With Pressure Switch / With Pressure Sensor | None (Pressure Port Plug available) / None (Pressure Port Plug not available) / With Standard Pressure Gauge / With Pressure Switch / With Pressure Sensor | None (Pressure Port Plug available) / None (Pressure Port Plug not available) / With Standard Pressure Gauge / With Pressure Switch / With Pressure Sensor | None (Pressure Port Plug available) / None (Pressure Port Plug not available) / With Standard Pressure Gauge | - | None (Pressure Port Plug available) / None (Pressure Port Plug not available) / With Standard Pressure Gauge |
Loading...Tải…
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy