(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
Caution
thận trọng
Compact noise filter for suppressing device malfunction due to external noise.
[Features]
·External impulse high attenuation type.
·ø1 noise filter.
·Single-phase 250 V.
·Lineup from 4 to 30 A. (4 A/6 A/10 A/16 A/20 A/30 A)
·It uses a quick and easy push-down terminal block (with screw fall prevention function).
·It has mounting compatibility with NAC, NAH, NAM, NMP and can be used properly according to the application.
·Ground capacitor that can be selected according to the application.
·DIN rail mounting type is available as an option.
[Applications]
·Ideal for industrial equipment with sequencers and computers.
NAP series
External impulse high attenuation type
Single-phase 250 V
It uses a quick and easy push-down terminal block (With screw fall prevention function)
1 Series name
2 Rated current
3 Ground capacitor code
4 Option D: DIN rail mounting type
Code | Leakage current Input 125/250 V 60 Hz | Capacitor capacity (Nominal value) |
---|---|---|
000 | 5 µA / 10 µA max | N/A |
471 | 50 µA / 100 µA max | 470 pF |
472 | 0.5 mA / 1.0 mA max | 4,700 pF |
Item | NAP-04-472 | NAP-06-472 | NAP-10-472 | NAP-16-472 | NAP-20-472 | NAP-30-472 |
---|---|---|---|---|---|---|
Rated Voltage〔V〕 | AC 1⌀ 250 / DC250 | |||||
Rated current〔A〕 | 4 | 6 | 10 | 16 | 20 | 30 |
Test voltage (Between terminals and mounting plates) | 2,500 V AC (cutoff current = 20 mA), 1-minute, normal temperature normal humidity | |||||
Insulation resistance (Between terminals and mounting plates) | 500 V DC 100 MΩ min normal temperature normal humidity | |||||
Leakage current 125/250 V 60 Hz | 0.5 mA / 1.0 mA max | |||||
Voltage drop | 1.0 V max | |||||
Safety standard certified temperature | - 25 to + 85°C (Refer to the derating characteristics) | |||||
Operating Temperature | - 40 to + 85°C (Refer to the derating characteristics) | |||||
Operating Humidity | 20 to 95% RH (No condensation) | |||||
Storage temperature/humidity | - 40 to + 85°C, 20 to 95% RH (No condensation) | |||||
Vibration | 10 to 55 Hz, 19.6 m/s^2 (2 G), period 3 minutes X, Y, Z direction 1 hour each | |||||
Impact | 196.1 m/s^2 (20 G) 11 ms X, Y, Z direction 1 time each | |||||
Safety Standard | UL1283, CSA C22.2 No.8 (C-UL), DIN EN60939 VDE0565 Teil 3-1, ENEC (Except for DC input) | |||||
External dimensions (excluding protrusions) / weight | 53 × 41 × 92 mm (W × H × D) / 300 g max (Option: for -D, refer to the drawing) |
Since this product uses a push-down terminal block, it is shipped in the following conditions.
1 Terminal block cover is stored.
2 Terminal block screw is retained on the upper side.
Standard type
DIN rail mounting type
Grounding through a DIN rail may not provide the proper noise attenuation effect.
Grounding should be done by connecting to the protective ground terminal (PE) of the noise filter main body.
There are 2 protective ground terminals, but you can use it even by connecting only one of them.
NAP-06-472
Attenuation characteristic (Static characteristics)
Pulse attenuation characteristics pulse width 1 µs
NAP-10-472
Attenuation characteristic (Static characteristics)
Pulse attenuation characteristics pulse width 1 µs
NAP-16-472
Attenuation characteristic (Static characteristics)
Pulse attenuation characteristics pulse width 1 µs
NAP-20-472
Attenuation characteristic (Static characteristics)
Pulse attenuation characteristics pulse width 1 µs
NAP-30-472
Attenuation characteristic (Static characteristics)
Pulse attenuation characteristics pulse width 1 µs
Part Number |
---|
NAP-06-472 |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng | Rated Current (A) | Mounting Method | H (mm) |
---|---|---|---|---|---|---|---|
551,360 VND | 1 Piece(s) | 4 Day(s) or more | 6 | Fasten With Screws | 41 |
Loading...Tải…
Input Type | Single-Phase | Wiring Method | Screw Fastening | Safety standards | UL / CUL / CSA |
---|---|---|---|---|---|
D(mm) | 92 | W(mm) | 53 | Representative standards (VDE) | Corresponds To |
Representative standards (ENEC) | Corresponding (excluding time of DC input) | External pulse voltage high attenuation | Corresponds To | Leak current value(mA max) | 1(250V60Hz) |
Please check the type/dimensions/specifications of the part NAP-06-472 in the NAP Series Single-Phase Noise Filter (General-Purpose / Single-Stage Filter / External Pulse Voltage Attenuation) series.Vui lòng kiểm tra kiểu/kích thước/thông số kỹ thuật của phần NAP-06-472 trong chuỗi NAP Series Single-Phase Noise Filter (General-Purpose / Single-Stage Filter / External Pulse Voltage Attenuation).
Part Number |
---|
NAP-04-472-D |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to ShipSố ngày giao hàng | Rated Current (A) | Mounting Method | H (mm) |
---|---|---|---|---|---|---|---|
625,814 VND | 1 Piece(s) | 4 Day(s) or more | 4 | DIN Rail | 48 |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy