(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
Caution
thận trọng
Direct heat exchanger with circulating water in the factory.
[Features]
・ For temperature control in a temperature range that does not require a refrigerator
・ Many achievements in semiconductor process equipment with high temperature stability, wide temperature range, failure diagnosis, external communication, etc.
・ UL, SEMI standard compliant, CE marking
・ Inverter type selectable
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng | RoHS | Cooling capacity | Optional specifications | Pump Inverter Control |
---|---|---|---|---|---|---|---|---|
- | 1 Piece(s) | Quote | - | 2 kW | None | None | ||
- | 1 Piece(s) | Quote | 10 | 2 kW | Analog communication | None | ||
- | 1 Piece(s) | Quote | 10 | 2 kW | Device net communication | None | ||
- | 1 Piece(s) | Quote | 10 | 2 kW | Device net communication, automatic circulation fluid collection function | None | ||
- | 1 Piece(s) | Quote | 10 | 2 kW | DI control kit | None | ||
- | 1 Piece(s) | Quote | 10 | 2 kW | DI control kit, automatic circulation fluid collection function | None | ||
- | 1 Piece(s) | Quote | 10 | 2 kW | None | Yes (pump inverter type) | ||
- | 1 Piece(s) | 31 Day(s) | - | 2 kW | Analog communication | Yes (pump inverter type) | ||
- | 1 Piece(s) | Quote | 10 | 2 kW | Analog communication, automatic circulation fluid collection function | Yes (pump inverter type) | ||
- | 1 Piece(s) | Quote | 10 | 8 kW | None | None | ||
863,766,000 VND | 1 Piece(s) | 32 Day(s) | - | 8 kW | Analog communication | None | ||
- | 1 Piece(s) | Quote | 10 | 8 kW | Analog communication, DI control kit | None | ||
- | 1 Piece(s) | Quote | 10 | 8 kW | Analog communication, automatic circulation fluid collection function | None | ||
- | 1 Piece(s) | Quote | 10 | 8 kW | Device net communication | None | ||
- | 1 Piece(s) | Quote | 10 | 8 kW | Device net communication, automatic circulation fluid collection function | None | ||
- | 1 Piece(s) | Quote | 10 | 8 kW | NPT fitting | None | ||
- | 1 Piece(s) | Quote | 10 | 8 kW | DI control kit | None | ||
- | 1 Piece(s) | Quote | 10 | 8 kW | DI control kit, automatic circulation fluid collection function | None | ||
- | 1 Piece(s) | Quote | - | 8 kW | None | Yes (pump inverter type) | ||
- | 1 Piece(s) | Quote | 10 | 8 kW | Analog communication | Yes (pump inverter type) | ||
- | 1 Piece(s) | Quote | 10 | 8 kW | Analog communication, DI control kit | Yes (pump inverter type) | ||
- | 1 Piece(s) | Quote | 10 | 8 kW | Analog communication, DI control kit, automatic circulation fluid collection function | Yes (pump inverter type) | ||
- | 1 Piece(s) | 31 Day(s) | - | 8 kW | Device net communication | Yes (pump inverter type) | ||
- | 1 Piece(s) | Quote | - | 8 kW | Device net communication, DI control kit | Yes (pump inverter type) | ||
- | 1 Piece(s) | Quote | 10 | 8 kW | Device net communication, automatic circulation fluid collection function | Yes (pump inverter type) | ||
- | 1 Piece(s) | Quote | 10 | 8 kW | NPT fitting, automatic circulation fluid collection function | Yes (pump inverter type) | ||
- | 1 Piece(s) | Quote | 10 | 8 kW | DI control kit | Yes (pump inverter type) | ||
- | 1 Piece(s) | Quote | - | 8 kW | DI control kit, automatic circulation fluid collection function | Yes (pump inverter type) | ||
879,471,000 VND | 1 Piece(s) | 32 Day(s) | - | 15 kW | None | None | ||
- | 1 Piece(s) | Quote | 10 | 15 kW | Analog communication | None | ||
- | 1 Piece(s) | Quote | 10 | 15 kW | Analog communication, NPT fittings, DI control kit | None | ||
- | 1 Piece(s) | Quote | 10 | 15 kW | Analog communication, DI control kit | None | ||
- | 1 Piece(s) | Quote | 10 | 15 kW | Device net communication | None | ||
- | 1 Piece(s) | Quote | 10 | 15 kW | Device net communication, NPT fitting, DI control kit, automatic circulation fluid collection function | None | ||
- | 1 Piece(s) | Quote | 10 | 15 kW | Device net communication, automatic circulation fluid collection function | None | ||
- | 1 Piece(s) | Quote | 10 | 15 kW | NPT fitting, DI control kit | None | ||
- | 1 Piece(s) | Quote | 10 | 15 kW | DI control kit | None | ||
- | 1 Piece(s) | 31 Day(s) | - | 15 kW | Circulating fluid automatic collection function | None | ||
- | 1 Piece(s) | Quote | 10 | 15 kW | None | Yes (pump inverter type) | ||
- | 1 Piece(s) | Quote | 10 | 15 kW | Analog communication | Yes (pump inverter type) | ||
- | 1 Piece(s) | Quote | 10 | 15 kW | Analog communication, DI control kit | Yes (pump inverter type) | ||
- | 1 Piece(s) | Quote | 10 | 15 kW | Device net communication | Yes (pump inverter type) | ||
- | 1 Piece(s) | Quote | 10 | 15 kW | Device net communication, NPT fitting, SI unit fixed | Yes (pump inverter type) | ||
- | 1 Piece(s) | Quote | 10 | 15 kW | Device net communication, DI control kit, automatic circulation fluid collection function | Yes (pump inverter type) | ||
- | 1 Piece(s) | Quote | 10 | 15 kW | DI control kit, automatic circulation fluid collection function | Yes (pump inverter type) | ||
- | 1 Piece(s) | Quote | 10 | 15 kW | Circulating fluid automatic collection function | Yes (pump inverter type) | ||
- | 1 Piece(s) | Quote | - | 30 kW | None | None | ||
- | 1 Piece(s) | Quote | 10 | 30 kW | Analog communication | None | ||
- | 1 Piece(s) | Quote | 10 | 30 kW | Device net communication | None | ||
- | 1 Piece(s) | Quote | 10 | 30 kW | Device net communication, automatic circulation fluid collection function | None | ||
- | 1 Piece(s) | Quote | 10 | 30 kW | NPT fitting | None | ||
- | 1 Piece(s) | Quote | 10 | 30 kW | NPT fitting, DI control kit | None | ||
- | 1 Piece(s) | Quote | 10 | 30 kW | DI control kit | None | ||
- | 1 Piece(s) | Quote | - | 30 kW | None | Yes (pump inverter type) | ||
- | 1 Piece(s) | Quote | 10 | 30 kW | Analog communication | Yes (pump inverter type) | ||
- | 1 Piece(s) | Quote | 10 | 30 kW | Analog communication, device net communication, NPT fitting, SI unit fixing, DI control kit, automatic circulation fluid collection function | Yes (pump inverter type) | ||
- | 1 Piece(s) | Quote | 10 | 30 kW | Analog communication, DI control kit, automatic circulation fluid collection function | Yes (pump inverter type) | ||
- | 1 Piece(s) | Quote | 10 | 30 kW | Analog communication, automatic circulation fluid collection function | Yes (pump inverter type) | ||
- | 1 Piece(s) | Quote | 10 | 30 kW | Device net communication, NPT fitting, SI unit fixing, DI control kit, automatic circulation fluid collection function | Yes (pump inverter type) | ||
- | 1 Piece(s) | Quote | 10 | 30 kW | Device net communication, NPT fitting, automatic circulation fluid collection function | Yes (pump inverter type) |
Loading...Tải…
Setting Temperature Range | 20 to 90℃ |
---|
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy