(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.

  • Viewed
    Products
    Sản phẩm
    đã xem
    최근 본
    상품
    查看产品 查看產品
  • My
    Components
    Linh kiện
    của tôi
    나의 부품 我的部件 我的部件
  • Cart
Recently Viewed Products
X
My Components
X
Cart item(s)
X
Loading...
  • [Thông báo] Cập nhật địa chỉ kho tập kết hàng hóa tại khu vực miền Nam của MISUMI Việt Nam. Xem chi tiết.
    [Announcement] Update on warehouse address in the Southern region of MISUIMI Vietnam. See more. 
  • [Cảnh Báo] Thủ Đoạn Lừa Đảo Từ Nhân Viên Giao Hàng – Yêu Cầu Trả Phí Ship. Xem chi tiết.
    [Warning] Fraud Calling from Shipper - Asking to Pay Shipping Fee. See more.

Water Hammer Relief, Pilot Operated 2 Port Solenoid Valve VXR21/22/23 Series

Water Hammer Relief, Pilot Operated 2 Port Solenoid Valve VXR21/22/23 Series
You can add up to 6 items per a category to the compare list.

Part Number :
  • Order Qty :
  • Price :
    ---
  • Total Price :
    ---
  • Days to ship :
    ---

Select part number to Order Now/ Add to Cart

  • CAD Data unavailable

(i)

Caution

thận trọng

  • Product images may be representative images. Refer to the catalog for details.

Product Description

SMC Solenoid Valve.
[Features]
· Water hammer is alleviated.
· Easy to disassemble and reassemble in a short time.

Water Hammer Relief, Pilot Operated 2 Port Solenoid Valve VXR21/VXR22/VXR23 Series, For Water/Oil, Normally Closed (N.C.) Specifications

Normally closed (N.C.) external appearance

Normally closed (N.C.) external appearance

Normally closed (N.C.) display symbol

Normally closed (N.C.) display symbol

*When the valve is closed IN and OUT are blocked, but the fluid cannot be blocked when the pressure at port 2 exceeds the pressure at port 1.

Model / Valve Specifications (Normally Open)

ConnectionOrifice Diameter
mm ø
ModelMinimum Operating Pressure Differential *2
MPa
Maximum Operating Pressure Differential *2 MPaFlow Rate CharacteristicsMaximum System Pressure *2
MPa
Weight *1
g
ThreadWaterOilWater/Oil
KvConversion Cv
1/220VXR2150-040.041.00.75.76.51.51,250
3/420VXR2150-066.47.51,250
125VXR2260-1010.3121,730
1 1/435VXR2270-1218.9222,900
1 1/240VXR2380-1425.7303,700
250VXR2390-2042.8484,600

*1: This is the grommet value. Add 10 g for conduit types, 30 g for DIN terminals, 60 g for terminals respectively.
*2 See the SMC catalog for details on the maximum and minimum operating pressure differentials and the maximum system pressure.

Solenoid Specifications

ModelPower SupplyFrequency
Hz
Apparent Power VAPower Consumption
W (Holding)
Temperature Increase °C
(Rated Voltage)
InrushHolding
VXR21AC5020114.545
601773.235
DC---655
VXR22AC5040187.560
603512650
DC---860
VXR23AC5050211165
6045179.560
DC---11.565
  • *Value is for when rated voltage is applied and ambient temperature is 20°C ±5°C.
  • *It is possible to change the coil from AC to DC during use. However, it is not possible to change from DC to AC.
    (The lack of a shading coil for DC means there may be a humming.)
  • *The return voltage is 20% or more of the rated value for an AC power supply and 2% or more of the rated value for a DC power supply.
  • *The allowable voltage fluctuation is ±10% of the rated voltage.

Fluid Temperature and Ambient Temperature

Temperature ConditionsPower SupplyFluid Temperature °CAmbient Temperature
°C
Water
(Standard)
Oil
(Standard)
High Temperature Water *2
(D)
High Temperature Oil *2
(D)
MaximumAC6060808060
DC4040--40
MinimumAC/DC1-5*1---10

*1 50 mm2/s or less.
*2 The D within the parenthesis ( ) is the option symbol.

Structure / Principle Part Materials

Normally closed (N.C.) diagram

Normally closed (N.C.) diagram

NumberPart NameMaterial
StandardOption
1BodyCAC408-
2BonnetCAC408-
3O-RingNBRFKM
4Diaphragm
Assembly
SUS, brass, NBRSUS, brass, FKM
5Valve SpringSUS-
6Core AssemblySUS, copper-
7Armature
Assembly
SUS, NBRSUS, FKM
8Return
Spring
SUS-
9Coil
Assembly
Class B moldedClass H molded

Operation

  • When the coil (9) is energized, the armature assembly (7) is attracted into the core of the core assembly (6), opening pilot valve (A). When the pilot valve (A) is opened, the pressure in the pressure action chamber (B) falls, opening the main valve (C).
  • When the coil (9) is not energized, the pilot valve (A) closes and the pressure in the pressure action chamber (B) increases, closing the main valve (C).

Water Hammer Relief

  • A check valve mechanism is provided on the (E) side of the supply orifices (D) and (E). Supply into the pressure action chamber (B) can be controlled in 2 stages by moving the diaphragm assembly (4). After cutting power, orifice (E) will become blocked when the port of main valve (C) reduces in its opening diameter. Having this slower valve closing speed helps alleviate the water hammer effect.

Water Hammer Relief, Pilot Operated 2 Port Solenoid Valve VXR21/VXR22/VXR23 Series, For Water/Oil, Normally Open (N.O.) Specifications

Normally open (N.O.) external appearance

Normally open (N.O.) external appearance

Normally open (N.O.) display symbol

Normally open (N.O.) display symbol

*When the valve is closed IN and OUT are blocked, but the fluid cannot be blocked when the pressure at port 2 exceeds the pressure at port 1.

Model / Valve Specifications (Normally Open)

ConnectionOrifice Diameter
mm ø
ModelMinimum Operating Pressure Differential *2
MPa
Maximum Operating Pressure Differential *2 MPaFlow Rate CharacteristicsMaximum System Pressure *2
MPa
Weight *1
g
ThreadWaterOilWater/Oil
KvConversion Cv
1/220VXR2152-040.040.70.65.76.51.51,270
3/420VXR2152-066.47.51,270
125VXR2262-1010.3121,770
1 1/435VXR2272-1218.9222,900
1 1/240VXR2382-1425.7303,700
250VXR2392-2042.8484,600

*1: This is the grommet value. Add 10 g for conduit types, 30 g for DIN terminals, 60 g for terminals respectively.
*2 See the SMC catalog for details on the maximum and minimum operating pressure differentials and the maximum system pressure.

Solenoid Specifications

ModelPower SupplyFrequency
Hz
Apparent Power VAPower Consumption
W (Holding)
Temperature Increase °C
(Rated Voltage)
InrushHolding
VXR21AC502512550
602083.535
DC---650
VXR22AC504520855
6040156.545
DC---850
VXR23AC50602510.560
6050209.550
DC---11.555
  • *Value is for when rated voltage is applied and ambient temperature is 20°C ±5°C.
  • *Changing coils from AC to DC and vice-versa during use is not possible because of the different core shape.
  • *The return voltage is 20% or more of the rated value for an AC power supply and 5% or more of the rated value for a DC power supply.
  • *The allowable voltage fluctuation is ±10% of the rated voltage.

Fluid Temperature and Ambient Temperature

Temperature ConditionsPower SupplyFluid Temperature °CAmbient Temperature
°C
Water
(Standard)
Oil
(Standard)
High Temperature Water *2
(D)
High Temperature Oil *2
(D)
MaximumAC6060808060
DC4040--40
MinimumAC/DC1-5*1---10

*1 50 mm2/s or less.
*2 The D within the parenthesis ( ) is the option symbol.

Structure / Principle Part Materials

Normally open (N.O.) diagram

Normally open (N.O.) diagram

NumberPart NameMaterial
StandardOption
1BodyCAC408-
2BonnetCAC408-
3O-RingNBRFKM
4Diaphragm
Assembly
SUS, brass, NBRSUS, brass, FKM
5Valve SpringSUS-
6Core
Assembly
SUS, copper, NBR, POM, PTFESUS, copper, FKM, PTFE
7Coil
Assembly
Class B moldedClass H molded

Operation

  • When the coil (7) is energized, the opened pilot valve (A) closes and the pressure in the pressure action chamber (B) increases, closing the main valve (C).
  • Cutting power to the coil (7) will open the closed pilot valve (A) and decrease the pressure in the pressure action chamber (B), opening the main valve (C).

Water Hammer Relief

  • A check valve mechanism is provided on the (E) side of the supply orifices (D) and (E). Supply into the pressure action chamber (B) can be controlled in 2 stages by moving the diaphragm assembly (4). After energizing, orifice (E) will become blocked when the port of main valve (C) reduces in its opening diameter. Having this slower valve closing speed helps alleviate the water hammer effect.

Water Hammer Relieving Characteristic Diagrams

VXR2150, VXR2152, VXR2260, VXR2262

Water hammer relieving characteristic diagram 1

Water hammer relieving characteristic diagram 1

Water Hammer

(Example) The VXR2 Series helps greatly mitigate the severe water hammer effect generated by use of normal solenoid valves. This prevents vibrations and damage to piping, equipment and devices. The graph above shows an overview of how the water hammer effect is mitigated.

How to Read the Graph

When there is 30 m of SGP piping with the same diameter as the solenoid valve being used, the maximum pressure will be approximately 1.1 MPa with an initial pressure of 0.5 MPa. (4 to 7 MPa for general use solenoid.)

VXR2270, VXR2272, VXR2380, VXR382, VXR2390, VXR2392

Water hammer relieving characteristic diagram 2

Water hammer relieving characteristic diagram 2

How to Read the Graph

When there is 30 m of SGP piping with the same diameter as the solenoid valve being used, the maximum pressure will be approximately 0.8 MPa with an initial pressure of 0.5 MPa. (2 to 4 MPa for general use solenoid.)

 

*See the SMC catalog for information other than that detailed above.

Part Number
VXR2150-06-1DZ
VXR2150-06-1TZ
VXR2150-06-2D
VXR2150-06-2DZ
VXR2150-06-3D
VXR2150-06-3DZ
VXR2150-06-3G
VXR2150-06-3T
VXR2150-06-4D
VXR2150-06-4DZ
VXR2150-06-4G
VXR2150-06-4TZ
VXR2150-06-5D
VXR2150-06-5DZ
VXR2150-06-5G
VXR2150-06-5TZ
VXR2150-06-6DS
VXR2150-06-6TS
VXR2150-06-7DS
VXR2150-06F-5DL
VXR2150-06F-5TZ
VXR2150-06F-7DS
VXR2150-06N-3D
VXR2150-06N-3DS
VXR2150-06N-5D
VXR2150-06N-5DS
VXR2150-06N-5GS
VXR2150-06T-3DZ
VXR2150A-06-5DZ
VXR2150A-06F-5DZ
VXR2150D-06-4G
VXR2150D-06-4T
VXR2150D-06F-1TS
VXR2152-06-2D
VXR2152-06-2DL
VXR2152-06-3G
VXR2152-06-4G
VXR2152-06-5DZ
VXR2152-06-5G
Part NumberPriceMinimum Order Qty.Volume DiscountDays to ShipSố ngày giao hàngRoHSApplicable Fluid Operating Environment Switching Type Connection Type Plumbing Thread Nominal Insulation Class Voltage Sealing materials Option Detailed type Lead wire electrical entry Body size

4,415,200 VND

1 Piece(s) 32 Day(s) --StandardNormally Open[Rc (R)] Rc3/4B100 V AC 50/60 HzNBRSurge voltage suppressor / With lightStandardDIN terminal20A

-

1 Piece(s) Quote --StandardNormally Open[Rc (R)] Rc3/4B100 V AC 50/60 HzNBRSurge voltage suppressor / With lightStandardConduit terminal20A

-

1 Piece(s) Quote --StandardNormally Open[Rc (R)] Rc3/4B200 V AC 50/60 HzNBRNoneStandardDIN terminal20A

-

1 Piece(s) Quote --StandardNormally Open[Rc (R)] Rc3/4B200 V AC 50/60 HzNBRSurge voltage suppressor / With lightStandardDIN terminal20A

4,198,400 VND

1 Piece(s) 32 Day(s) --StandardNormally Open[Rc (R)] Rc3/4B110 V AC 50/60 HzNBRNoneStandardDIN terminal20A

-

1 Piece(s) Quote --StandardNormally Open[Rc (R)] Rc3/4B110 V AC 50/60 HzNBRSurge voltage suppressor / With lightStandardDIN terminal20A

3,980,800 VND

1 Piece(s) 32 Day(s) --StandardNormally Open[Rc (R)] Rc3/4B110 V AC 50/60 HzNBRNoneStandardGrommet20A

4,234,400 VND

1 Piece(s) 32 Day(s) --StandardNormally Open[Rc (R)] Rc3/4B110 V AC 50/60 HzNBRNoneStandardConduit terminal20A

4,198,400 VND

1 Piece(s) 32 Day(s) --StandardNormally Open[Rc (R)] Rc3/4B220 V AC 50/60 HzNBRNoneStandardDIN terminal20A

4,415,200 VND

1 Piece(s) 32 Day(s) --StandardNormally Open[Rc (R)] Rc3/4B220 V AC 50/60 HzNBRSurge voltage suppressor / With lightStandardDIN terminal20A

3,980,800 VND

1 Piece(s) 32 Day(s) --StandardNormally Open[Rc (R)] Rc3/4B220 V AC 50/60 HzNBRNoneStandardGrommet20A

4,396,800 VND

1 Piece(s) 32 Day(s) --StandardNormally Open[Rc (R)] Rc3/4B220 V AC 50/60 HzNBRSurge voltage suppressor / With lightStandardConduit terminal20A

4,198,400 VND

1 Piece(s) 32 Day(s) --StandardNormally Open[Rc (R)] Rc3/4B24 V DCNBRNoneStandardDIN terminal20A

4,415,200 VND

1 Piece(s) 32 Day(s) --StandardNormally Open[Rc (R)] Rc3/4B24 V DCNBRSurge voltage suppressor / With lightStandardDIN terminal20A

3,980,800 VND

1 Piece(s) 32 Day(s) --StandardNormally Open[Rc (R)] Rc3/4B24 V DCNBRNoneStandardGrommet20A

-

1 Piece(s) Quote --StandardNormally Open[Rc (R)] Rc3/4B24 V DCNBRSurge voltage suppressor / With lightStandardConduit terminal20A

-

1 Piece(s) Quote --StandardNormally Open[Rc (R)] Rc3/4B12 V DCNBRWith surge suppressorStandardDIN terminal20A

-

1 Piece(s) Quote --StandardNormally Open[Rc (R)] Rc3/4B12 V DCNBRWith surge suppressorStandardConduit terminal20A

-

1 Piece(s) Quote --StandardNormally Open[Rc (R)] Rc3/4B240 V AC 50/60 HzNBRWith surge suppressorStandardDIN terminal20A

-

1 Piece(s) Quote --StandardNormally OpenG3/4B24 V DCNBRWith lightStandardDIN terminal20A

-

1 Piece(s) Quote 10-Standard / Water Hammer CompatibleNormally ClosedG3/4B-NBRSurge voltage suppressor / With lightStandardConduit terminal20A

-

1 Piece(s) Quote 10-Standard / Water Hammer CompatibleNormally ClosedG3/4B240 V AC 50/60HzNBRWith surge suppressorStandardDIN terminal20A

-

1 Piece(s) Quote --StandardNormally OpenNPT3/4B110 V AC 50/60 HzNBRNoneStandardDIN terminal20A

-

1 Piece(s) Quote 10-Standard / Water Hammer CompatibleNormally ClosedNPT3/4B110 V AC 50/60 HzNBRWith surge suppressorStandardDIN terminal20A

-

1 Piece(s) Quote --StandardNormally OpenNPT3/4B24 V DCNBRNoneStandardDIN terminal20A

-

1 Piece(s) Quote 10-Standard / Water Hammer CompatibleNormally ClosedNPT3/4B-NBRWith surge suppressorStandardDIN terminal20A

-

1 Piece(s) Quote --StandardNormally OpenNPT3/4B24 V DCNBRWith surge suppressorStandardGrommet20A

-

1 Piece(s) Quote 10-Standard / Water Hammer CompatibleNormally ClosedNPTF3/4B110 V AC 50/60 HzNBRSurge voltage suppressor / With lightStandardDIN terminal20A

5,030,400 VND

1 Piece(s) 32 Day(s) -OilStandardNormally Open[Rc (R)] Rc3/4B24 V DCFKMSurge voltage suppressor / With lightFuel oil (up to 60°C)DIN terminal20A

-

1 Piece(s) Quote 10OilStandard / Water Hammer CompatibleNormally ClosedG3/4B-FKMSurge voltage suppressor / With lightFuel oil (up to 60°C)DIN terminal20A

4,723,200 VND

1 Piece(s) 32 Day(s) -Water / OilStandardNormally Open[Rc (R)] Rc3/4H220 V AC 50/60 HzFKMNoneHot water (up to 80°C) / Fuel oil (up to 80°C)Grommet20A

4,976,000 VND

1 Piece(s) 32 Day(s) -Water / OilStandardNormally Open[Rc (R)] Rc3/4H220 V AC 50/60 HzFKMNoneHot water (up to 80°C) / Fuel oil (up to 80°C)Conduit terminal20A

-

1 Piece(s) Quote 10Water / OilStandard / Water Hammer CompatibleNormally ClosedG3/4H100 V AC 50/60 HzFKMWith surge suppressorHot water (up to 80°C) / Fuel oil (up to 80°C)Conduit terminal20A

4,560,000 VND

1 Piece(s) 32 Day(s) --StandardNormally Closed[Rc (R)] Rc3/4B200 V AC 50/60 HzNBRNoneStandardDIN terminal20A

-

1 Piece(s) Quote --StandardNormally Closed[Rc (R)] Rc3/4B200 V AC 50/60 HzNBRWith lightStandardDIN terminal20A

4,343,200 VND

1 Piece(s) 32 Day(s) --StandardNormally Closed[Rc (R)] Rc3/4B110 V AC 50/60 HzNBRNoneStandardGrommet20A

4,343,200 VND

1 Piece(s) 32 Day(s) --StandardNormally Closed[Rc (R)] Rc3/4B220 V AC 50/60 HzNBRNoneStandardGrommet20A

4,776,800 VND

1 Piece(s) 32 Day(s) --StandardNormally Closed[Rc (R)] Rc3/4B24 V DCNBRSurge voltage suppressor / With lightStandardDIN terminal20A

-

1 Piece(s) Quote --StandardNormally Closed[Rc (R)] Rc3/4B24 V DCNBRNoneStandardGrommet20A

Loading...Tải…

  1. 1

Basic InformationThông tin cơ bản

Type Electromagnetic Type Driving Type Pilot Type Number of Solenoids Single Solenoid
Application Single Item Body material CAC408, copper