(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
Caution
thận trọng
Fieldbus System (For Output) EX120/121/122 Series compatible with a variety of communication networks.
[Features]
· Output type for solenoid valve.
SI Unit model number notation image
Communication Specifications | Terminating Resistor | Not provided |
---|---|---|
Internal Current Consumption (Unit) | 100 mA or less | |
Environment Resistance | Enclosure | IP20 |
Operating Temperature Range | 0 to +55°C (valve 8 points ON) 0 to +50℃ (valve 16 points ON) | |
Operating Humidity Range | 35 to 85% RH (No condensation) | |
Withstand Voltage | 1,500 V AC for 1 minute between external terminal and housing | |
Insulation Resistance | 500 V DC, 2 MΩ or more between external terminal and housing |
Model | EX12□-SDN1 | EX12□-SDN1-X26 | EX12□-SMJ1 | EX12□-SCS1 EX12□-SCS2 | |
---|---|---|---|---|---|
Communication Specifications | Protocol Name | DeviceNetTM | CC-Link | Made by OMRON CompoBus/S | |
Version*1 | Release 2.0 | Ver. 1.10 | - | ||
Communication Speed | 125/250/500 kbps | 156/625 kbps 2.5 M / 5 M / 10 Mbps | 750 kbps | ||
Configuration File*2 | EDS file | CSP + file | - | ||
I/O Occupation Area (No. of Inputs/No. of Outputs) | 16/16 | 0/16 | 32/32 (1 station, remote I/O stations) | SCS1: 0/16 SCS2: 0/8 | |
Power Supply Voltage | For Control | 11 V DC to 25 V DC | 15 to 30 V DC | 14 V DC to 26.4 V DC | |
For Valve | 24 V DC +10%/-5% | ||||
Output Specifications | Output Format | Sink/NPN (positive common) | |||
Number of Outputs | 16 points | SCS1: 16 points SCS2: 8 points | |||
Connection Load | SMC solenoid valve 24 V DC, 2.1 W or less with surge voltage suppressor circuit | ||||
Output if Communication Error | Clear | Hold/Clear (Switch setting) | Clear | Hold/Clear (Switch setting) | |
Standards | CE marking | ||||
Weight | EX120: 110 g or less, EX121: 140 g or less, EX122: 130 g or less | ||||
Accessories | Communication connector 1 pc., power supply connector 1 pc. | - |
Model | EX12□-SUH1 | EX12□-SCM1 | EX12□-SCM3 | |
---|---|---|---|---|
Communication Specifications | Protocol Name | Made by NKE Fieldbus H System | CompoNet | |
Communication Speed | 29.4 kbps | 93.75 kbps/1.5 Mbps/3 Mbps/4 Mbps | ||
Configuration File | - | EDS file*1 | ||
I/O Occupation Area (No. of Inputs/No. of Outputs) | 0/16 | |||
Power Supply Voltage | For Control | 24 V DC ±10% (Common power supply) | 14 V DC to 26.4 V DC | |
For Valve | 24 V DC +10%/-5% | |||
Output Specifications | Output Format | Sink/NPN (positive common) | Sink/NPN (positive common) | Source/PNP (Negative common) |
Number of Outputs | 16 points | |||
Connection Load | SMC solenoid valve 24 V DC, 2.1 W or less with surge voltage suppressor circuit | |||
Output if Communication Error | Clear | Hold/Clear (setting via network) | ||
Standards | - | CE marking | ||
Weight | EX120: 110 g or less EX121: 140 g or less EX122: 130 g or less | EX120: 100 g or less EX121: 120 g or less EX122: 110 g or less (including accessories) | ||
Accessories | - | Power supply connector (EX9-CP2) 1 pc.*2 |
(Unit: mm)
EX120-SDN1(-X26) dimensional drawing
(Unit: mm)
EX120-SMJ1, SCS□, SUH1 dimensional drawing
(Unit: mm)
EX120-SCM□ dimensional drawing
(Unit: mm)
EX121-SDN1(-X26) dimensional drawing
(Unit: mm)
EX121-SMJ1, SCS□, SUH1 dimensional drawing
(Unit: mm)
EX121-SCM□ dimensional drawing
(Unit: mm)
EX122-SDN1(-X26) dimensional drawing
(Unit: mm)
EX122-SMJ1, SCS□, SUH1 dimensional drawing
(Unit: mm)
EX122-SCM□ dimensional drawing
Part Number |
---|
EX121-SCS2 |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng | Valve Interface | Communication Protocol | Output Format |
---|---|---|---|---|---|---|---|
- | 1 Piece(s) | Quote | Flat cable DIN rail mounting | OMRON CompoBus/S (8 output) | Sink/NPN (Positive common) |
Loading...Tải…
Type | Solenoid |
---|
Please check the type/dimensions/specifications of the part EX121-SCS2 in the Fieldbus System (for Output), EX120/121/122 Series series.Vui lòng kiểm tra kiểu/kích thước/thông số kỹ thuật của phần EX121-SCS2 trong chuỗi Fieldbus System (for Output), EX120/121/122 Series.
Part Number |
---|
EX120-SCS2 |
EX120-SDN1 |
EX120-SMJ1 |
EX121-SDN1 |
EX121-SMJ1 |
EX121-SUH1 |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to ShipSố ngày giao hàng | Valve Interface | Communication Protocol | Output Format |
---|---|---|---|---|---|---|---|
6,399,200 VND | 1 Piece(s) | 32 Day(s) | Plug-In | OMRON CompoBus/S (8 output) | Sink/NPN (Positive common) | ||
15,606,400 VND | 1 Piece(s) | 32 Day(s) | Plug-In | DeviceNet (16 input/16 output) | Sink/NPN (Positive common) | ||
7,335,200 VND | 1 Piece(s) | 32 Day(s) | Plug-In | CC-Link | Sink/NPN (Positive common) | ||
16,542,400 VND | 1 Piece(s) | 32 Day(s) | Flat cable DIN rail mounting | DeviceNet (16 input/16 output) | Sink/NPN (Positive common) | ||
8,271,200 VND | 1 Piece(s) | 32 Day(s) | Flat cable DIN rail mounting | CC-Link | Sink/NPN (Positive common) | ||
- | 1 Piece(s) | Quote | Flat cable DIN rail mounting | NKE Fieldbus H system | Sink/NPN (Positive common) |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy