(!) Since support from Microsoft will end on January 14th, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Vì lý do Microsoft kết thúc hỗ trợ cho Windows 7 vào ngày 14/01/2020, Windows 7 sẽ là hệ điều hành không được khuyến khích sử dụng với trang web này từ ngày 15/12/2019.
Select part number to Order Now/ Add to Cart
Caution
thận trọng
With the adoption of the external pilot system, the 182 series boasts the diverse functions of the 2- and 3-port valves and is very versatile with its compact body.
*This series is having CAD data modified. Please wait till the corrections are done.
External Appearance
Valve main parts material
Item | Basic Form | For positive pressure | For vacuum |
---|---|---|---|
Direct piping / F, FE type manifold | 182E1 | V182E1 | |
A type manifold | A182E1 | AV182E1 | |
Operating fluid | Air | ||
Operating method | External pilot type | ||
Flow rate characteristics | Sonic conductance C dm^3 / (s*bar)^*1 | 2.04 | |
Effective cross-sectional area [Cv value] mm^2 | 10.2 (0.57) | ||
Piping connection diameter^*2 | Main | Rc1/8 | |
Pilot | M5 × 0.8 | ||
Lubrication | Not required | ||
Operating pressure range MPa | Main | 0 to 0.7 | -100 kPa to 0.15 |
Pilot | 0.2 to 0.7 | ||
Proof pressure resistant MPa | 1.05 | ||
Response time^*3 ms ON / OFF | 12 V DC, 24 V DC | 15 or less / 25 or less | |
100 V AC, 200 V AC | 15 or less / 15 or less | ||
Maximum operating frequency: Hz | 5 | ||
Operating temperature range (atmosphere and operating fluid)°C | +5 to +50 | ||
Impact resistance m/s^2 | 1,373.0 (Axial direction 294.2) | ||
Mounting Direction | Free |
*1 The value of sonic conductance is a calculated value, not an actual measurement value.
*2 For details, refer to the digital catalog and the table of manifold piping connection diameters. .
*3 Value when the air pressure is 0.5 MPa.
182E1 (For positive pressure)
V182E1 (For vacuum)
For positive pressure, stable switching from low pressure to high pressure (0 to 0.7 MPa) is possible.
Since there are no restrictions on the piping port position and flow direction, it can be used as a 2- or 3-port valve for NC (normally closed) NO (normally open), as well as a selector valve (2-pressure switching valve) or divider valve (distribution valve).
For vacuum, as with positive pressure, NC (normally closed) NO (normally open) shared 2-3 port valve that is not restricted by the piping port position and flow direction.
Since it can be used in combination with positive pressure, it can also be used as a valve for vacuum breakage and forced withdrawal.
Part number details
Non-ion specifications are described in NCU before the basic format.
Manifold part number details
Non-ion specifications are described in NCU before the basic format.
The valve type is specified for each station. For positive pressure and vacuum, the manifold is common, but mixed mounting is not possible.
It is a product with combining design know-how and production technology cultivated since the manufacturer founding to meet customer needs, and it is developed after undergoing strict inspection.
Part Number |
---|
182E1-PLL AC100V |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to ShipSố ngày giao hàng | Application | Number of Ports | Mounting Orientation | Voltage | Plumbing | Wiring Type | Lead Length (mm) | LED Indicator |
---|---|---|---|---|---|---|---|---|---|---|---|---|
2,229,084 VND | 1 Piece(s) | 53 Day(s) or more | Single Item Operating | 3-port valve | Direct | AC100V | Direct piping | L-Connectors | 300 | Available |
Loading...Tải…
Type | Electromagnetic Valve | Specifications | Oil-Free | Number of Solenoids | Single |
---|---|---|---|---|---|
Status at Power Off | Self-reset(spring return) | Pipe Port Type | Rc | Plumbing Thread Nominal | 1/8 |
Manual Switch(Ø) | 80 | Driving Type | Pilot-operated Spool | CV Value | 0.23 |
Seal Type | Soft seal | Pressure Rating(MPa) | 0 to 0.7 | Pilot Air Supply | External Parts |
Manual Button | Non-locking type | Sub-base | N/A |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy